Buffer Tank Connection; Tank Heater; Base Pan Heater; Alternative Outdoor Sensor - Panasonic WH-SDC0305J3E5 Mode D'emploi

Pompe à chaleur air-eau
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 306
Menu

Buffer tank connection

5.7
To connect tank to the system
and if selected YES, to set
T temperature.
• The optional PCB connectivity
must be selected YES to
enable the function.
• If the optional PCB
connectivity is not selected,
the function will not appear on
the display.

Tank heater

5.8
To select external or internal
tank heater and if External is
selected, set a timer for the
heater to come on.
* This option is available if Tank
connection is selected (YES).

Base pan heater

5.9
To select whether or not
optional base pan heater is
connected.
* Type A - The base pan heater
activates only during
deice operation.
* Type B - The base pan heater
activates when outdoor
ambient temperature is
5 °C or lower.

Alternative outdoor sensor

5.10
To select an alternative outdoor
sensor.

Bivalent connection

5.11
To select to enable or disable
bivalent connection.
Yes
To select either auto control
pattern or SG ready input
control pattern.
* This selection only display
to select when optional pcb
connection set to Yes.
Default Setting
Setting Options / Display
No
Yes
Set T for Buffer
5 °C
Tank
Internal
External
Tank heater ON time
0:20
set.
No
Yes
Set base pan heater
A
type*.
No
No
Auto
EN
25