Door closing mechanism

The door is equipped with a self-closing system.
The door can be opened by using the foot pedal. This leaves both hands free when
filling the cabinet.

Dry refrigeration

Applies only to cabinets with dry refrigeration.
+ -
P
Dry refrigeration is activated by pressing the keys
and
at the same time,
and hold both keys down for a few seconds until the display shows H0, release the
keys - dry refrigeration mode is now activated.
+ -
P
To return to normal operation, press the keys
and
at the same time, and
hold the keys down for a few seconds until the display shows H1, release the keys -
normal operation mode is now activated.

Power failure

On power failure, the control remembers the temperature setting and restarts the
cabinet when current is restored. If the power failure persists for some time, the
control might revert to the factory setting.

Cleaning

The cabinet should be cleaned internally with a mild soap solution at suitable
intervals and checked thoroughly before it is put into operation again.
For the external maintenance – use steel oil.
Cleansing agents containing chlorine or compounds of chlorine as well as other
corrosive means, are not to be used, as they might cause corrosion to the stainless
panels inside the cabinet and the evaporator system.
The compressor compartment and in particular the condenser must be kept free
from dust and dirt. This is best done with a vacuum cleaner and a brush.
Do not flush compressor compartment and evaporator with water as this may cause
short-circuits in the electrical system.
NB!: Always disconnect the cabinet before cleaning.