Hoover HH64DB3T Notice D'emploi Et D'installation page 7

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 28
"Installation must conform to the standards & directives."
Manufacturer declines all responsibility for any damage that
might be caused by unsuitable or unreasonable use.
WARNING: Manufacturer cannot be held responsible for any incident
or its consequences that may arise during the use of an appliance not
linked to the earth, or linked to an earth whose continuity is defective.
Before any electrical operation, please check the supply tension
shown on the electricity meter, the adjustment of the circuit- breaker,
the continuity of the connection to earth to the installation and that the
fuse is suitable.
The electrical connection to the installation should be made according
to the rated power of the Appliance; this should be made via an Omni
pole cut-out switch.
If the appliance has a socket outlet, it must be installed so that the
socket outlet is accessible.
The yellow/green wire of the power supply cable must be connected to
the earth of both power supply and appliance terminals.
For any questions regarding power supply cord refer to After Sales
Service or a qualified technician.
If the hob is fitted with power supply cord, this shall be connected only
to a power supply of 220-240 V between phase and neutral.
It is however possible to connect the hob to:
Three Phase 220-240 V3
Three Phase 380-415 V2N
To proceed to the new connection, please follow below instructions:
Before making the connection, make sure that the installation is
protected by a suitable fuse, and that it is fitted with wires of a large
enough section to supply the appliance normally.
Turn over the hob, glass side against the working top, taking care to
protect the glass.
Open the cover in the following sequence:
1
2
- unscrew the cable clamp "1";
- find the two tabs located on the sides;
- put the blade of a flat screw-driver in front of each tab "2" e
"3", push in and press;
- remove the cover.
To release the power supply cord:
- Remove the screws retaining the terminal block which
contains the shunt bars and the conductors of the supply cord;
- Pull out the supply cord.
Operations to be carried out to make a new connection:
- Choose the power supply cable in accordance with the
recommendations in the table;
- Pass the power supply cable into the clamp;
- Strip the end of each conductor of the supply cord on a 10 mm length,
by taking in account the requested length of the cord for the
connection to the terminal block;
- According to the installation and with the help of shunt bars which you
should have recovered in the first operation, fix the conductor as
shown on the chart;
- Fix the cover;
- Screw the cable clamp.
3
06 GB
Note: make sure the terminal board screws are tight.
Operations to be carried out to make a new connection:
- Choose the power supply cable in accordance with the
recommendations in the table;
- Pass the power supply cable into the clamp;
- Strip the end of each conductor of the supply
cord on a 10 mm length, by taking in account
the requested length of the cord for the
connection to the terminal block;
- According to the installation and with the help
of shunt bars which you should have recovered
in the first operation, fix the conductor as shown
on the chart;
- Fix the cover;
- Screw the cable clamp.
ATTENTION:
If it should be necessary to replace the power supply cord, connect the
wire in accordance with following colors/codes:
Connection to the terminals on the terminal block
LAY OUT
MONOPHASE or TWO PHASES 220-240 V
Cable
3x2,5 mm
HO5V2V2F
THREE PHASES 220-240 V
Cable
4x1,5 mm
HO5V2V2F
THREE PHASES 380-415 V
Cable
4x1,5 mm
HO5V2V2F
380-415V 2N ~
PE
L1
L2
220-240V ~
PE
L
L1 / L2 / L3 = Phase
LAY OUT
"1-6"
"7"
~
2
3x4 mm
2
3~
2
4x1,5 mm
2
2N~
2
4x1,5 mm
2
220-240V 3 ~
L3
L2
PE
L1
220-240V 2 ~
L2
PE
L1
N = Neutral
PE = Earth
SHUNT

Publicité

Table des Matières
loading

Table des Matières