3.0 MOVING AN AUTOMATIC VENDING MACHINE
3.1 Moving and transport (Fig.3.1)
The transport of the distributor must be effected by competent personnel.
The distributor is delivered on a pallet; for the shifting use a trolley and move
it slowly in order to avoid capsizing or dangerous movements.
Avoid :
– lifting the distributor with ropes or presses
– draggin
g the distributor
– upset or lay down the distributor during transport
– give jolts to the distributor
Avoid as the distributor:
– bumping it
– overloading it with other packages
– exposing it to rain, to cold or sources of heat
– keeping it in damp places
The construction company is not liable for any damage which may be caused
for the partial or complete non-observance of the warning notices indicated
above.
3.2 Stocking
For eventual stocking, avoid laying several machines over each other, maintain
it in vertical position, in dry places with temperatures not inferior to 1°C.
3.3 Packing
The distributor is protected with polystyrene angles and by a transparent
film in polypropylene.
The automatic distributor will be delivered packed, assuring both a me-
chanical protection and
protection against damages from the external
environment.
On the package labels are applied indicating:
maneouver with care
don't turn upside-down
protect from the rain
don't superimpose
protect from sources of heat
not resistant against bumps
type of distributor and serial number.
3.4 Reception
Upon reception of the automatic distributor you need to check that the same
has not suffered damages during the transport.
If damages of any nature are noticed place a claim with the forwarder im-
mediately.
At the end of the transport the packing must result without damages
which means it must not :
– present dents, signs of bumps, deformations or damages of the external
packaging
– present wet zones or signs that could lead to suppose that the packing
has been exposed to rain, cold or heat.
– present signs of tampering
3.5 Unpacking
-
Free the distributor from the packaging , cutting the protective film in
which it is wrapped, along one of the protection angles (Fig.3.2).
-
Remove the distributor from transport pallet, unscrewing the screws (A)
that block the fixing cross staff heads to the pallet (Fig.3.3).
– Release the pallet and insert the 4 feet into the threaded slots (fig. 3.4)
freed of the screws (A)
– Remove the key from the ventilation grille on the back of the vending
machine (Fig.3.5).
Open the vending machine door and remove the components in the following
list:
coin box
skirting board
The packing material must not be le ft accessible to others, as it is
a potential environmental pollution sources. For the disposal contact
qualified companies authorized.
www.vendival.com
4.0
INSTALLATION
4.1 Positioning
– If positioned near a wall, the back must be at a minimum distance of 8
cm from this wall (Fig.4.1), so as to allow normal ventilation of the cooling
unit. Never cover the distributor with cloths or similar objects.
– Position the distributor and level it using the pre-mounted adjustable feet
(Fig.4.2). Make sure that the distributor does not have an inclination of
more than 2°.
– Make sure that the grills behind and under the radiator are always free
and not obstructed by dust or similar objects in order to guarantee perfect
ventilation for the cooling unit.
– It is recommended that the distributor be fixed to the wall using
the two brackets provided. Fix them first to the distributor (fig.4.3)
and then to the wall.
WARNINg! Do not position the device near inflammable objects, keep
a minimum safety distance of 30 cm.
Bianchi Vending Group declines every responsibilty for any damage due
to the non-observance of the rules about machine positioning.
If the machine is installed in an emergency exit corridor, ensure that when
the distributor door is open there is still enough space to pass. (Fig.4.1).
4.2 Main Power supply connection
The distributor is predisposed to function with mono-phase 220-230V, 50Hz
tension of net and is protected with 10A fuse.
We suggest to check that:
– the tension of net doesn't have a difference of more than ± 6%
– The power supply output is able to bear the power load of the machine.
– use a system of diversified protection
– position the machine in such a way as to ensure that the plug remains
accessible
The machine must be connected to earth in observance with the current
safety norms.
For this reason, verify the plant's earth wire connection to ascertain that it
is efficient and it answers national and European safety electric standards.
If necessary require the intervention qualified personnel for the verification
of the plant.
– The distributor is equipped
3x1,5mm², with SCHUKO plug (Fig.4.4).
– The sockets that are not compatible with that of the machine must be
replaced. (Fig.4.5).
– The use of extension, adapters and/ or multiple plugs is forbidden.
– In some models, specific plugs are assembled for the destination place.
Bianchi Vending Group spa declines all responsibility for damages deriving
for the complete or partial failure to observe these warnings.
Should the power cable be found to be damaged, immediately disconnect
from the power socket.
The power supply cables are to be replaced by skilled personnel.
4.3 Starting up of the unit
The distributor is equipped with safety switch (Fig.4.6) that disconnects the
machine whenever the door is opened (see electric schema).
In case of necessity, therefore, open the door or disconnect taking of the
machine from the power supply.
The clamp of the power cable junction box under tension
(Fig.4.7)
– For some operations is however necessary operate with the door open
but with the distributor connected.
It is possible for qualified technical personnel, to operate in this way, by
inserting the special plastic key , supplied with the distributor, into the
door switch and rotating it 90° (Fig.4.8).
The opening and the possible connection with the distributor's door
open must be performed only by authorized and technically qualified
personnel. Don't leave the distributor open and unguarded.
Give the key only to qualified personnel.
Every time the distributor is switched on, a diagnosis cycle begins to check
the position of the parts in motion and the number of motors there are per
drawer.
4.4
Refrigerator unit
The machine is equipped with a refrigerator unit that allows the machine to
reach and maintain a temperature between +2°C and +15°C to keep the
products cool.
-
The refrigerator unit can be easily replaced in the case of a malfunction.
See the maintenance chapter.
-
The internal temperature is detected by an electronic probe and can be
preset when programming the electronic card.
13
Tel. 902 07 07 59 Whastapp 615 35 50 96
ENGLISH
with a power supply cable of H05VV-F