6.7. System event log
To access the system event log, press the "Diagnostics" key. The system accesses the diagnostic screens both of the
electronic ballast and the UV lamp power circuit discussed in Section 5.6.
Pressing the navigation key at the top right of the screen, you will access the log screen of certain system events from
its connection.
This register is automatically deleted each time the system is disconnected (only in firmware versions prior to 11102-XXX and 11202-XXX).
6.8. Configuration of system auxiliary parameters
The "Configuration" screen allows to modify several auxiliary parameters of the system.
To access the "Configuration" screen, press the "Diagnostics" button. The system accesses the diagnostic screens both
of the electronic ballast and the UV lamp power circuit discussed in Section 6.6.
Repeatedly pressing the navigation key located on the top right of the screen, the "Configuration" screen will appear.
INTERNAL DIAMETER OF THE FLOW CELL
The configuration screen allows to modify the diameter of the flow cell. Unless it was necessary to change the location
of the flow sensor from its default position in the UV reactor to another point in the installation, because the measured
flow rates were outside the detection range of the sensor (5 ... 100 cm/s), this parameter will always match the inner
diameter of the UV reactor, thus not being necessary its modification.
MP 50 ... MP 140
10.51 " (267 mm.)
21
MP 300 ... MP 450
13.78 " (350 mm.)