Astralpool Heliox UV MP Manuel D'installation page 11

Système de traitement uv
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

MP 450 model (220/240V version)
T. block
Control panel input
PE
2
POWER 220/240 VAC / 50-60 Hz. / 3-phase
3
4
PE
UV REACTOR BONDING
5
UV LAMP-1 OUTPUT
6
7
UV LAMP-2 OUTPUT
8
9
SW-11
10
SW-12
11
SW-21
12
SW-22
13
14
SI5004 FLOW SENSOR INPUT
15
16
17
UVC-SE RADIATION SENSOR INPUT
18
19
20
21
TM4411 / MBT5250 TEMPERATURE SENSOR INPUT
22
23
FLOW SWITCH INPUT
24
25
EXTERNAL STOP INPUT
26
(1)
Not supplied with the unit.
(2)
Not supplied with the unit. Bonding must be made with a solid copper conductor minimum No. 8 AWG (USA) / 6 AWG (Canada).
(3)
Default bridged input. We strongly recommend to interlock the UV
system with the recirculation pump contactor through one of its NO
auxiliary contacts.
Cable
GROUND
PHASE (R)
(1)
PHASE (S)
PHASE (T)
(2)
GROUND
LP-045/1-1
RED
LP-045/2-1
RED
LP-045/1-2
WHITE
LP-045/2-2
WHITE
BLACK "1"
LP-045-1
BLACK "2"
BLACK "1"
LP-045-2
BLACK "2"
BROWN
EVC-005
WHITE
BLUE
WHITE
BROWN
EVC059
BLACK
GREY
BROWN (or Blue)
EVC-005 or
WHITE (or Green)
MBTC-05
BLUE (or Red)
(3)
POTENTIAL-FREE CONTACT
(4)
POTENTIAL-FREE CONTACT
(4)
Input logics
9