Safety Instruction - Kroll KG/UB20 Notice D'utilisation

Masquer les pouces Voir aussi pour KG/UB20:
Table des Matières

Publicité

Enclosed fibre mat
Installation
Combustion chamber with a convex rear panel
KG/UB20P = 20 mm
KG/UB20 - KG/UB200 = 25 mm
Combustion chamber with a vertical rear panel panel
Put the ceramic fibre plate on the floor of the ceramic fibre mat.
The ceramic fibre board must cover the burning chamber bottom completely and laterally be
placed as high as possible. Pay attention, that the flues are not covered.
If you do not need the mat, keep the bag closed or dispose it according to the effective waste
regulations.
The ceramic fibre mat must be put at the rear end of each cast iron
boiler.
The mat must be put on the floor of the boiler, raising to the rear pa-
nel (see picture) in order to avoid creation of a coating due to a drop
shaped combustion.
The mat can be folded so that it fits into the combustion chamber.
The remaining material can be cut off.
When you modify the ceramic fibre mat, make sure that proper pro-
tection is guaranteed.
Attention
Combustion chamber - Ø at installa-
tion of ZVP-tube min. 180 mm
~10 mm
**30 - 10 mm
**260 mm
KG/UB20P = ** 300 mm
KG/UB20
KG/UB55
KG/UB70
KG/UB100
KG/UB150
KG/UB200

Safety instruction

** marked measure are
= ** 320 mm
= ** 360 mm
minimum size!
= ** 360 mm
= ** 380 mm
= ** 400 mm
= ** 400 mm
Put the ceramic fibre plate
(039363) at the rear of the com-
bustion chamber. (Depending on
boiler type and dimensions of the
combstion chamber.)
The ceramic fibre mat is adap-
ted to the convex rear panel of
the combustion chamber.
37