(2)Cranking Test
After entering the second start system test function , the press OK key as
following:
Starting the engine as prompted, tester will automatically complete the cranking test
and display the result.
Normally, cranking voltage value lower than 9.6V is regarded as abnormal and it is OK
if it is higher than 9.6V.
Test result of the tester includes actual cranking voltage and actual cranking time.
When cranking test is abnormal, battery test result will also be displayed at the same
time.
PBT 550 battery conductance tester User Manual
Cranking Test
START ENGINE
Cranking Test
RPM DETECTED
Cranking Test
TIME
1758ms
CRANKING NORMAL
10.56V
Cranking Test
TIME
1020ms
CRANKING
9.12V
EN -
LOW