5 5 5 5 PROGRAMMING
PROGRAMMING
PROGRAMMING
PROGRAMMING
AQUONTROLLER has three menus:
RAPID INSTALLATION MENU
RAPID INSTALLATION MENU
RAPID INSTALLATION MENU
RAPID INSTALLATION MENU
You can view and edit the basic parameters of operation for quick and easy programming, such as: language,
motor rated current, pressure. Detail parameters see section 5.1.
MAINTENANCE MENU
MAINTENANCE MENU
MAINTENANCE MENU
MAINTENANCE MENU
You can view and modify various functions in the rapid setup menu as additional parameters for quick and
complete calibration system. Detail parameters see section 5.2.
EXTENDED MENU (access with password)
EXTENDED MENU (access with password)
EXTENDED MENU (access with password)
EXTENDED MENU (access with password)
You can view and edit all the operating parameters, including the rapid setup menu and maintenance menu.
It is necessary to access this menu, mainly in case of problems stopping the inverter and / or oscillation.
Detail parameters see section 5.3.
Key functions
KEYS PRESSED
+
+
+ ENTER
-
-
- ENTER
ENTER
ENTER
+ (3 seconds long
+ - ENTER (all at once)
5.1 RAPID INSTALLATION MENU
5.1 RAPID INSTALLATION MENU
5.1 RAPID INSTALLATION MENU
5.1 RAPID INSTALLATION MENU
IMPORTANT: The first time is essential to have
IMPORTANT: The first time is essential to have the pump rating data
IMPORTANT: The first time is essential to have
IMPORTANT: The first time is essential to have
Parameter list of the Rapid Installation Menu
Parameter list of the Rapid Installation Menu
Parameter list of the Rapid Installation Menu
Parameter list of the Rapid Installation Menu
Parameter
Parameter
Parameter
Parameter
Language
Nom MotorCurrent
Nominal Value
Auto-Start
EFFECT
Increase
Fast increase
Very fast increase
Decrease
Fast decrease
Very fast decrease
Save (only if password has been entered)
Show next parameter
Show previous parameter
Go to maintenance menu (from main menu)
Go to extended menu (from main menu)
Read
Read
Unit
Unit
Min
Min
Read
Read
Unit
Unit
Min
Min
(R) /
(R) /
(R) /
(R) /
Write
Write
Write
Write
(RW)
(RW)
(RW)
(RW)
RW
A
0.45
RW
bar
0.3
RW
ON
the pump rating data
the pump rating data
the pump rating data
Max
Max
Default
Default
Max
Max
Default
Default
MMW07: 12
MMA07: 12
4.5
MMW12: 19
MMA12: 19
MMW07: 7.5
MMA07: 10
2.5
MMW12: 7.5
MMA12: 10
OFF
OFF
Description
Description
Description
Description
Language selection
Set the nominal current of motor. See
data plate.
Set the required system pressure (set
point)
ON: AQUONTROLLER will start
automatically whenever power is
restored to power.
OFF: AQUONTROLLER not start
automatically each time power is
restored to power. In this case the
activation dell'AQUONTROLLER must be
done manually.
en en
en
en
43