Installation And Use - Koshin PX-55011 Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

INSTALLATION AND USE

• An acceptable motor-control switch shall be provided at the time of installation.
• Thermally protected
1. This pump works under an automatic surface control
system whereby it is automatically switched on and off by
a fl oat switch.
2. The pump starts automatically when the water level rises
and the fl oat comes up to the ON water level, and stops
automatically when the water level falls and the fl oat
comes down to the OFF water level.
3. The ON and OFF water levels can be adjusted by
loosening the cord band bolt. However, the length of the
cord between the cord band and the fl oat switch should
be between 50mm and 150mm, otherwise the fl oat switch
will not operate normally.
4. The fl oat switch should be installed where it does not
come into contact with walls or is any other obstructions.
5. The pump should not be installed where water is
discharged directly onto the fl oat.
AFTER USING PUMP
1. In cold climates, do not allow pump to freeze.
Remove pump from water to prevent damage due to freezing.
2. Completely drain and dry pump of water before storing.
CAUTION
1. Leak Current Breaker
For home use, attach a leak current breaker, GFCI (offered separately) to ensure safety.
2. Connect the power source
Absolutely refrain from connecting this pump to any other power source than 110V
AC or 220V AC, 50Hz.
3. Water to use
Absolutely refrain from using the pump for any oil, sea water, strong alkaline or strong
acidic solution, or any agricultural chemicals.
4. Do not run dry!
Idling can cause trouble, to prevent short cycling place pump at deepest position as possible.
5. Handling of power cord (cabtype cable)
a. Never lift or move pump by power cord. Only lift by handle or tie rope supplied to handle.
b. Select and use proper size extension cord. Do not run extension cord in water.
6. Using in bath, etc.
Do not enter the water when pump is being used.
- 3 -
3
3
Float switch
Cord Band
The ON
water level
350~
410mm
The OFF water level
: 100~130mm
4
4
Leave
space
5
5
EN

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Px-55022Px-55022aPxl-52511Pxl-52522

Table des Matières