4) CONT BUTTON
This button is used to select CONT mode. In this mode, the fog machine sprays fog continuously.
The volume of fog is set with the smoke output control (2). When you press this button, the CONT
led lights on. Push another time this button to disable this function
5) MANUAL BUTTON
This button is used to select manual mode. Press this button to spray 100% of volume as long as
you press the button. When you release the button, the spray of fog stops.
WIRELESS REMOTE CONTROL
When the fog machine is ready for use, keep button "A" or "B" pressed to produce fog. Release the
button to stop fog output.
INSTALLING THE BATTERY IN THE REMOTE CONTROL
• Place the remote face down on a flat surface.
• Push the compartment cover into the direction of the arrow to slide the battery compartment
open.
• Remove the old battery and install the new one (23A 12V alkaline) with the correct polarity.
• Gently slide the battery compartment closed. It locks automatically.
RECOMMENDATIONS FOR BATTERIES
This symbol indicates that used batteries should not be disposed of with household waste but deposed correctly in accordance with
your local regulations..
Batteries shall not be exposed to excessive heat such as sunshine, fire or the like.
When the internal batteries are not to be used, remove them to avoid damage caused by battery leakage or corrosion.
: Danger of explosion if battery is incorrectly placed. Only replace by the same or equivalent type.
ATTENTION
:Do not swallow the battery. Danger of chemical burns. Keep new and old batteries out of the reach of children.
WARNING
If the battery compartment doesn't close properly, stop using the product and keep it out of the reach of children.
If you are in doubt whether the batteries have been swallowed or introduced into any other part of the body, contact immediately a doctor.
MENU DISPLAY
Button functions:
MENU: Press to go to the next page. If you are in an operating mode, press to exit the mode.
UP/TIMER: Increase the value, or set up the timer
DOWN: Decrease the value
ENTER: Confirm the value and exit
MENU MAP
8.8.8.8
The machine is in warm up status
FOG
The machine is ready for use
A000
Set interval time (1-120 minutes)
F000
Set the continuous fog production time (1-120 seconds)
C000
Set the fog output volume (1-100%)
d000
Set the DMX address (001-511)
TIMER AND VOLUME SETTING:
When FOG is displayed, press MENU button to go to A000 page and set up the interval time.
Then go to F000 and set up the time of continuous fog emission.
After that go to C000 page and set up the fog volume.
Press MENU to go back to the FOG page.
Press UP/TIMER button and set up the timer countdown (When it is set to A000, it will countdown
in seconds. When it is set to A001-A120, it will countdown in minutes).
Press MENU button to cancel and exit.
EN
4
© Copyright LOTRONIC 2021