SET UP
2
During the end limits adjustment, there is a one-second delay in motor operation.
2.1. Connect the motor
to
the
setting
switch
(ref.: 2006024).
2.2. Check the rotation direction:
Connect the switch to the mains, then
press ▲:
a. If the tube turns in the "up" direction, go
to step 2.3.
b. If the tube turns in the "down" direction, invert the brown (2) and black (3) wires on the motor, and repeat
the test.
2.3- End limit adjustment: The procedure used to set the end limits depends on the equipment of the
product (see table below):
Available devices
Top stop
-
*This setting is especially suitable for "ZIP screens" or for any other specific driven product with a heavy
load bar and a top stop.
SETTING 1: MANUALLY SETTING THE UP AND DOWN END LIMITS
1
2
≥ 3 s
≥ 3 s
>>
1- Press simultaneously on ▲ and ▼ for 3 seconds. The motor will run briefly in one direction and then in the
other*.
2- Press on ▲ for 3 seconds. The motor will run briefly in one direction and then in the other*.
3- Position the product on the desired up end limit using the ▲ and ▼ keys.
4- To memorize the up end limit, press ▼ twice, as follow:
- 1st press for 0,5 second without the motor rotation.
- 2nd press over 3 seconds, so the motor rotates briefly one way, then in the other*.
5- Position the product on the desired down end limit using the ▲ and ▼ keys.
6- To memorize the down end limit, press ▲ twice, as follow:
- 1st press for 0,5 second without the motor rotation.
- 2nd press over 3 seconds, so the motor rotates briefly one way, then in the other*.
7- Press the ▲ and ▼ keys simultaneously for at least 3 seconds. The motor will run briefly in one direction
and then in the other*.
After the operation 7, the settings are completed. There is no delay time any more. Go to stage §3.
* Press the buttons until the motor turns into the two directions.
PE
L
N
a
Setting to performed
Heavy load bar
-
-
3
0.5 s
>>
>>
OK
>>
See setting 1
See setting 2
See setting 3*
4
5
≥ 3 s
+
>>
6 s max.
T5ZSP
b
>>
6
0.5 s
≥ 3 s
>>
+
>>
6 s max.
Blue
Brown
Black
Green / Yellow
7
≥ 3 s
EN
2/5