SPECIFICATIONS
Power Supply Required. .........................................115 Volts
Motor Duty ........................................................Continuous
Circuit Requirement (minimum) ............................15.0 Amps
Discharge Adapter...........................................................1"
BOOSTING CITY WATER PRESSURE
Hazardous pressure. Never run the pump
against a closed discharge. To do so can boil the water inside
the pump, causing hazardous pressure in the pump causing
the risk of explosion and possibly scalding persons nearby.
See Figure 1.
Figure 1: Do Not Run Pump With Outlet Shut Off.
When using the pump as a high-pressure washer, use only a
reinforced high pressure hose or pipe for the discharge line.
When using a garden hose, install adapters to the pump suc-
tion and the discharge. The suction hose will require two
female ends. Either use a standard washing machine supply
hose or modify a short piece of standard 1" garden hose as a
suction line (See Figure 2).
Hazardous pressure. Do not shut off the hose
or the sprinklers while the pump is running. The hose or
sprinkler head may explode. For safety, add a 75PSI pressure
relief valve.
PERFORMANCE
Model
0
R100U
10
1117 0993
Output Pressure
10
20
8.5
8.0
3
Figure 2: Hose adapter installation.
Connect the Pump Inlet
to the Water Faucet
for use with Sprinklers.
Figure 3: Connect pump to a spigot for use with sprin-
klers. Connect with adapters supplied with pump.
30
40
7.5
7.0
Hose Adapters
Water Faucet
Hose
Adapters
3942 0401
Maximum
50
PSI
6.0
80
WA-253P7560