Changing The Master Code - CDVI Digicode Série Manuel D'installation

Masquer les pouces Voir aussi pour Digicode Série:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

INSTALLATION MANUAL
KCIN
Illuminated weatherproof Keypad with Remote Electronics 1, 2 or 3 relays
Default values
- Without codes.
- Illumination time: 10 seconds.
- Relay release time: 1 second.
- Code length: 5-digit.
- Master Code: 1 2 3 4 5.
- Programming security time :
120 secondes.
- Code length for sub master code:
Version 1 relay (Group 1) =
A and B,
Version 2 relays (Group 2) =
1 and 3
Version 3 relays (Group 3) =
4 and 6.
A. RESET MASTER CODE
AND USER CODES
1. Enter the master code twice
(1 2 3 4 5 default value master code).
2 beeps are emitted to confi rm
entry in programming mode.
2. Press A6 to reset the Master Code
and the User codes.
One beep is emitted. Press on A
and B to confi rm reset of all memory
of the keypad. Wait for two beeps.
The master code is restored
to its default value 1 2 3 4 5
and all the User codes are deleted
from the keypad. Once the reset
is completed then the keypad returns
to a stand-by operating mode.
OR
1. Cut the power. Put the jumper on P2.
2. Put the power back.
Wait approximately 3 seconds.
Two beeps are emitted to confi rm reset
of the keypad. Remove P2 jumper.
The master code is restored to its default
value 1 2 3 4 5 and all the User codes
are deleted from the keypad.
B. SETTING CODE LENGTH
1. Enter the master code twice.
(1 2 3 4 5 default value master code).
2 beeps are emitted to confi rm
entry in programming mode.
cdvi.com
8
8
cdvigroup.com
Audible signal:
The buzzer indicates different audible
signals. It can be turned off by cutting
the ST1 wire on the remote controller
1 short beep: Keypad powered
1 long beep: Data computing
in programming or access granted
2 short beeps: Enter or Exit
from programming
4 short beeps:
Data computing error.
Code length
The master code and the User codes
can be of 4 or 5-digit in length.
All the keypad keys can be used
to program a code. The master code
C. CHANGING THE MASTER CODE
and the Pin code can be of 4 or 5-digit
code. The master code CAN NOT
be used as a PIN code (User Pin code).
The master code CAN NOT be used
as a PIN code (User Pin code).
To delete a specifi c User pin Code replace
it by 0000 if code length is 4-digit format
or replace it by 00000 if the code
is in 5-digit format.
P2 jumper:
Reset master code and user codes
P3 jumper:
modifi cation of individual
code by the user
2. Press A4 to program the code length.
One beep is emitted. Press 4 or 5
for the digit code. One beep is emitted
to confi rm programming of the code length.
3. Press A5 to modify the master code.
One beep is emitted. Enter the new 4
or 5-digit master code. One beep is
emitted to confi rm programming
of the new master code.
4. Press B to exit from
programming mode.
2 beeps are emitted to confi rm that the key-
pad is in stand-by operating mode.
4 beeps indicate a data computing error.
The master code is used only
to enter in programming mode.
1. Enter the master code twice.
(1 2 3 4 5 default value master code).
2 beeps are emitted to confi rm
entry in programming mode.
2. Press A5 to modify the master code.
One beep is emitted. Enter the new 4
or 5 digit master code. One beep
is emitted to confi rm that the master
code is programmed.
3. Press B to exit from
the programming mode.
2 beeps are emitted to confi rm that the key-
pad is in stand-by operating mode.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Digicode kcin 1Digicode kcin 2Digicode kcin 3Digicode kcin

Table des Matières