5.
Connect the wiring that joins the control card to the communications card (see Cable E, light gray cabling
in the following figure).
To wire the communications card and control card at the station, you must keep in mind the following
connection positions:
The communications card switch (marked as G in the above figure) must have position 3 On.
4.
Connect the charging stations that make up the communication ring from the back, as indicated in the
following figures. In the first station, the RJ45 connector on the left is used to start the communication
ring (H) and the connector on the right to connect the modem (I).
First station
H
I
20
E
Pin
Color
1
White/Orange
2
Orange
Intermediate station
G
Signal
RS-485 B (+)
RS-485 A (–)
Final station