Control Panel

DEFROST LED
(Illuminates when defrost is activated)
DOWN button

Lock/Unlock the Control Panel

To lock the control panel:
Press and hold the UP
and DOWN
1.
Pof flashes on the display and the keyboard is locked.
2.
To unlock the control panel:
Press and hold the UP
and DOWN
1.
Pon flashes on the display and the keyboard is unlocked.
2.
Note:
If a button is not pressed for 10 seconds while using the control panel it times out and reverts to standby mode.
When parameters are being set the Setpoint LED will flash on the display.

Enter the Parameter Menu

Unlock the control panel, if locked.
1.
Press and hold the SET
2.
If necessary, press the SET
3.

Alter Parameter Value

Note: Your POLAR appliance has been preset with default parameters generally deemed suitable for normal operation. POLAR
recommend these preset values are used.
To alter the value, (if necessary):
With the desired parameter displayed, alter the value using the UP
1.
Press the SET
button to store the value.
2.
Note: The control panel will automatically move to the next parameter. To return to standby mode allow the control panel to time
out.

Parameter Descriptions

Parameter
Name
Operating
d1
temperature
Temperature
d2
Differential
d3
Temperature Range
d4
Compressor Activation
d5
Time Intervals
Maximum
d6
Temperature
Differential Alarm
Temperature
d7
Differential Alarm
Delay
UP button
buttons simultaneously for 10 seconds.
buttons simultaneously for 10 seconds.
button until 'd1' flashes on the display.
button repeatedly to scroll to the desired parameter (see "Parameter Descriptions" for parameter details).
Set the operating temperature of the appliance
The Temperature Differential is the allowed temperature difference above and
below the operating temperature before the compressor starts/cuts off
Set the minimum (d3) and maximum (d4) temperatures that the appliance
can fluctuate between
Enter the minimum time interval between the compressor turning off after
turning on.
Set an alarm to sound if the temperature inside the appliance exceeds the set
operating temperature by a specified amount
Set a delay before the temperature differential alarm is triggered
Pon
Display Panel
and DOWN
buttons.
Description
SETPOINT LED
(Illuminates when parameters are being set)
DEFROST button
SET button
Range
-2°C to 10°C
0 to 20°C
-40°C
95°C
0-999 seconds
0°C-50°C
0-99 minutes
UK
Default
Parameter
Value
2°C
3°C
2°C
10°C
99
50°C
0
2