3.6 Control of functions (fig. 2)
When the product is set up, always check the control functions.
These shall move easily and function satisfactorily.
Draught vent (A)
Left position
= closed
Right position
= fully open
Doorhandle (B)
Towards the left = open
Towards the right = closed
Doorhandle (C)
Towards the right = open
Towards the left = closed
Ash door (E)
Open the door by turning the knob counter-clockwise one half
rotation.
3.7 Ash removal
Jøtul F 500 has an ash pan which makes it easy to remove the ash.
1. Scrape the ash through the grate in the base plate and into
the ash pan. Use something like a glove to grab the handle
on the ash pan.
2. Make sure that the ash pan doesn't fill up so high that it keeps
ash from coming through the grate into the pan.
3. Make sure the door to the ash pan is securely shut when the
stove is in use.
For the rest, see description of how to handle ash in the Manual
on general use and maintenance in Point «6.1 Fire preventive
measures».
4.0 Service
Warning! Any unauthorised change to the product is illegal. Only
use original spare parts.
4.1 Changing the baffle plate
1. The baffle plate consists of a vermeculite plate, and rests on
top of the pipes that supply secondary air.
2. To remove, just lift it off and out
3. To install, follow the same procedure in opposite sequence.
Make sure the vermeculite plate is fitted closely against the
back wall. Be aware that the vermiculite plate may be damaged
by rough handling.
4. Then place the insulating blanket on top of the baffle plate.
4.2 Changing the burn plates
1. The stove has burn plates that are mounted to the sides and
fire bricks in the back.
2. Unfasten the screws and remove the burn plates. To reinstall,
make sure the insulation is properly fastened to back of the
burn plates.
3. The bricks at the back are easy to change. Simply lift up a
little and pull out.
5.0 Optional equipment
5.2 Connecting pipe for outdoor
ventilation - Cat. No. 221031
With the aid of a connecting pipe for outdoor ventilation and a
flexible tube, combustion air can be connected to the product
directly from the outside. In this manner, the fireplace will always
be supplied with the air needed to achieve proper combustion.
Fresh air supply direct from the exterior or from the chimney
with air vents
1. Insert the connecting pipe into the air inlet under the
product.
2. Unfold the pipe"s 3 flaps (fig. 5A) inside the air inlet.
3. Attach a flexible tube (Ø 80 mm) directly to the fireplace's
connecting pipe by using a hose clamp and attach it to the
wall outlet/chimney.
5.2 Rear heat shield- Cat.No. 350956
Assembly instruction follows the product.