9.3.
End setting of memory address
Keep pressing the [Menu] button until "Auto End"
appears on the display.
Enter the target value (the rotary knob) or enter and
accept the target value (the numeric buttons).
9.4.
Setting the cycle time:
Keep pressing the [Menu] button until "Auto Cycle"
appears on the display. You can set the cycle time
from 0 to 99999. The number 0 represents an infinite
loop.
Enter the target value (the rotary knob) or enter and
accept the target value (the numeric buttons).
9.5.
Setting the operating mode
Keep pressing the [Menu] button until "Auto MODE"
appears on the display to set the operating mode.
Use the knob to select the operating mode
• "0 Conti" means continuous operation mode;
• "1 Step" represents the step-by-step mode; a step
is taken when the trigger occurs.
9.6.
Activating / deactivating Auto Start
Set "Auto Status" to ON, the ("TIME") icon will light
up. This means that the device has entered the
automatic operation mode.
If the device is in the continuous operation mode, the
third parameter displayed represents the remaining
time for enable the settings in the current parameter
group. Press [On / Off] to start the output flow.
If the device is in the step mode, press [On / Off] to
start the output flow. The device generates an output
flow when the trigger occurs.
10.
Auxiliary function
The auxiliary function includes battery charging and
can extend other functions according to the user's
needs. Press the [•••] button (the button lights up) to
enter the auxiliary settings interface.
11.
Battery charging function
The device has a battery charging function.
Keep pressing the [•••] button until "BATTER STATUS"
appears on the display. Use the rotary knob to
activate the battery charging function; the [•••]
button lights up. Press the [Menu] button to select
the following functions:
• threshold charging voltage - UNDERV
• AC voltage - STATUV
• conservative charging current - TRICKL
• standard charging current - CHARGE
• current threshold termination - I OFF
• charging time - TIME
12.
Turning the output flow on / off
The On / Off button on the front panel is used to turn
the output power on and off.
13.
Panel lock
The [Lock] button is used to lock the front panel
to prevent the accidental entering of incorrect
operating parameters. Press the [Lock] button, the
button backlight will come on which means the front
panel is locked. All the other buttons and the rotary
knob are turned off except for the [Lock] button and
the [On / Off] button.
14.
Rotary knob
Press the rotary knob to change the cursor position.
15.
Protection function
The device is equipped with overvoltage protection
(O.V.P), overcurrent protection (O.C.P), over-power
protection (O.P.P) and over-temperature protection
(O.T.P).
The O.V.P and O.C.P levels can be set using the
[O.V.P. Level] and [O.C.P Level] buttons on the front
panel respectively.
The O.P.P function protects the device when the
EN
output power exceeds the rated power. The output
flow is switched off in the O.P.P. mode
The O.T.P function protects the device when too
high temperature is generated during the operating
process. The output flow is switched off in the O.T.P.
mode.
16.
Operating modes:
16.1. Constant voltage value:
Connect the load to the power connection (+, -). For
safety, turn off the output flow before connecting
the load to the output connections.
Set the present current limit value.
• Press the [Current], the control panel will enter
the current input mode. Set the desired value
using the number buttons or the knob.
Setting the desired output voltage value:
• Press the [Voltage], the control panel will enter
the voltage input mode. Set the desired value
using the numeric buttons or the knob.
Starting the output flow:
• Press the [On / Off] to turn on the flow. The device
will display the present flow value.
Confirming the constant voltage mode:
• Check whether the CV sign is displayed or not to
make sure that the output flow is in the constant
voltage mode. If the CC sign is displayed, the
current limit must be increased.
16.2. Constant current value:
Connect the load to the connection (+, -).
For safety, turn off the output flow before connecting
the load to the output connections
Set the voltage limit.
• Press the [Voltage], the control panel will enter
the voltage input mode. Set the desired value
using the numeric buttons or the knob.
Set the desired output current value:
• Press the [Current], the control panel will enter
the current input mode. Set the desired value
using the numeric buttons or the knob.
Starting the output flow:
• Press the [On / Off] to turn on the flow. The device
will display the present output flow value.
Confirming the constant current:
• Check whether the CC sign is displayed or not to
make sure that the output flow is in the constant
current mode. If a CV sign appears, the voltage
limit must be increased.
16.3. CV / CC switch
When the output current level reaches the set value
(ON), the CC (Constant Current) sign will light up and
the unit will operate in the constant current mode.
When the output voltage level reaches the set value,
the CV (Constant Voltage) sign will light up and the
unit will operate in the constant voltage mode.
The device automatically switches between DC mode
and constant voltage mode, depending on the load.
17.
Remote control
17.1. Remote
control
function
-
the
device
communicate with the computer via the RS232
interface and can be controlled by means of the
software as well as via the control panel. The
software is on the enclosed CD.
17.2. COM port setting
Set the COM port inside the computer according to
the list below:
• Baud rate: 9600
• Parity bit: None
• Data bit: 8
• Stop bit: 1
• Data flow control: None
04.03.2019
14
17.3. The device can be programmed using the SCPI
language commands. Detailed information and
programming instructions can be found next to
the product on the Expondo web pages. In case of
problems with finding instructions, please contact
customer service.
3.4. CLEANING AND MAINTENANCE
a)
Unplug the mains plug before each cleaning,
adjustment or replacement of accessories, or if the
device is not being used.
b)
Use only non-corrosive cleaners to clean the surface.
c)
After cleaning the device, all parts should be dried
completely before using it again.
d)
Store the unit in a dry, cool place, free from moisture
and direct exposure to sunlight.
e)
Never spray the device with water.
f)
Do not allow water to get inside the device through
vents in the housing of the device.
g)
Clean the vents with a brush and compressed air.
h)
The device must be regularly inspected to check its
technical efficiency and spot any damage.
i)
Check the power cord for insulation damage, signs
of burnout and other damage.
j)
Check if the terminal screws and housing screws are
not loose.
k)
For cleaning, use a soft cloth soaked in a solution of
water and a mild detergent.
l)
Do not use chemicals or cleaning products containing
harmful substances such as benzene, toluene, xylene
and acetone.
m)
To ensure fire protection, replace the fuse only with
the specified type and rating.
n)
To avoid electric shock, the power cord protective
grounding conductor must be connected to the
ground, do not remove covers.
o)
Service maintenance should be provided by qualified
personnel only.
Fuse replacement
PLEASE NOTE! The fuse should be replaced by a specialist!
1)
Disconnect the device from power supply.
2)
Disconnect the power cord and remove the fuse
holder.
3)
Replace the fuse, making sure that the parameters
are the same.
4)
Reinstall the fuse socket.
PLEASE NOTE! To avoid damage to the fuse socket,
can
do not use excessive force when removing and
installing the fuse socket.
04.03.2019
EN
15