Changing the battery
The battery must be changed without disassembling the manometer; otherwise, the calibration
will expire!
1. Pull the rubber safety cap down and clear the battery case.
2. Pull the (green) battery case out.
3. Always change the battery while maintaining the correct polarity.
4. Re-insert the battery case and cover the manometer with the safety cap.
(Check: The display screen illuminates briefly, as a so-called "segment test")
If - during the segment test – not all segments are indicated on the display screen, the
euroair digital may no longer be used to check and correct tyre pressure! Instead,
it must be sent in to a specialised dealer or to the manufacturer for repair.
TECHNICAL DATA
Protection class:
Pressure supply:
Maximum fill pressure:
Accuracy of readings:
Maximum deviation:
Fill hose:
Supply connector:
Temperature range:
Weight:
Power supply:
Valid norms:
IP54
max. 16 bar / 174 psi
12.0 bar / 174 psi
0.05 bar / 0.7 psi
< 0.08 bar / 1.16 psi
500 mm
Female screw thread G 1/2" with coupling plug DN 7.2
-10 °C up to +60 °C
approx. 1.0 kg
3 V coin cell CR 2450
EU guideline on electromagnetic compatibility (89/336/EEC)
version 93/31/EEC, EN61000-6-3(2011), EN61000-6-2(1999)
– 12 –