Operation

CHARGER OPERATION

The backup pump will activate automatically when the
backup sump water level rises far enough to trip the float
switch.
If the power to the charger circuit is interrupted, the
length of time that the backup pump will run depends on
the Ampere-hour capacity of the battery used, the battery
charge level, and the required vertical pumping distance.
Extended periods of operation (for example, during an
extended power outage) may exhaust the battery. The
battery charger will begin charging the battery as long as
the battery has a voltage differential of 3 Volts or more.
Recharge Time:
FP1800DCC-01: Approximately 100+ hours to fully
recharge a FP12V27DCC battery in a "dead battery
condition". The approximate recharge time for the
FP12V24DCC battery is 75 hours.
FP2800DCC: Approximately 19 hours to fully recharge
an FP12V27DCC battery in a "dead battery condition".
The approximate recharge time for the FP12V24DCC
battery is 15 hours. Industrial standards define a "dead
battery condition" as 9 Volts or less.
The 5 Stages of the Charging Process for
Model Number FP1800DCC-01:
NOTICE: The LED's will only illuminate once the AC
power has been applied. They will not light up if the
charger is not plugged in.
1. Yellow LED light flashing on and off indicates:
Prequalification test stage is in progress. Normal dura-
tion of this stage ranges from 18 minutes to 27 hours.
If a battery has been left in a state of discharge for
long periods this stage may require 27 hours to deter-
mine if the battery will even accept a charge.
2. Yellow LED light continuously on indicates:
Constant current charge stage. Charger is charging bat-
tery at the full rated output. This stage ends when the
battery terminal voltage reaches the factory preset volt-
age level.
TABLE IX – Capacity Ratings with FP12V27DCC (27M Marine Battery)
Model Numbers
Gallons Per Hour
Hours Available
Total Gallons Pumped
* These flow rates were obtained with a constant 12.7 VDC battery source. The actual GPH will vary due to a reduction in out-
put voltage from battery.
For parts or assistance, call Flotec Customer Service at
8 FEET
FP1800DCC-01 FP2800DCC
1,440
2,088
10
6.8
8,500
8,500
3. Yellow LED light continuously on also indicates:
Constant voltage charge stage. Battery cells are being
equalized.
4. Green LED light on indicates:
Float charge stage. Battery is charged and ready for
use. Charging has stopped. To maintain a full charge
on the battery, the yellow and green LED may alter-
nately turn back on. This means the charger is briefly
turning back on to keep the battery voltage from
falling below a preset voltage level.
5. Recycle charge stage:
The charger automatically initiates a charge cycle that
begins with the prequalification test stage. This occurs
once the battery has been in the float charge stage for
84 days.
The 5 Stages of the Charging Process for
Model Number FP2800DCC:
NOTICE: The LED's will only illuminate once the AC
power has been applied. They will not light up if the
charger is not plugged in.
1. Yellow "charging"(bicolor) LED flashing slowly
indicates:
A. Prequalification test stage is in progress. The normal
duration of this stage is 20 seconds to 3 minutes.
However, if a battery has been left in a state of dis-
charge for long periods or if the initial voltage is less
than 10.5 volts, this stage may require 5 hours to
determine if the battery will even accept a charge.
2. Yellow (bicolor)"charging" LED continuously on
indicates:
Constant current charge stage. Charger is charging
battery at full rated output.
3. Yellow (bicolor)"charging" LED flashing quickly
indicates:
Constant voltage charge stage. Battery cells are being
equalized. This could last up to 14.5 hours.
4. Green (bicolor) "charging" LED indicates:
Float charge stage. Battery terminal voltage is reduced
to a regulated voltage and battery is being maintained
at full charge.
VERTICAL PUMPING DISTANCE
10 FEET
FP1800DCC-01
FP2800DCC
1,200
1,770
11
6.0
7,000
7,000
1-800-365-6832
12 FEET
FP1800DCC-01 FP2800DCC
840
1,380
13
6.0
5,000
5,000