Start-Up
1.
Make sure the smoke machine is switched off before connecting it to the mains.
2.
Switch on the smoke machine.
3.
Press <VOLUME>.
4.
Adjust the smoke output volume with <UP> or <DOWN>.
DMX Configuration
To set the smoke machine in DMX mode:
1.
Connect the smoke machine to the mains, switch it on and let it warm up.
2.
Connect a DMX cable to the DMX input of the smoke machine and the DMX output of a controller
(not included).
3.
To activate the DMX function, press <FUNCTION> repeatedly until DMX512 ADD is displayed.
Select the start address from 1 to 512 with <UP> or <DOWN>.
Make sure that the starting address of the interconnected smoke machines
A DMX terminator is recommended for installations where the DMX cable has to run a long distance or is
in an electrically noisy environment (e.g. discos). The terminator prevents corruption of the digital
control signal by electrical noise. The DMX terminator is simply an XLR plug with a 120 Ω resistor
between pins 2 and 3, which is then plugged into the XLR output socket of the last device in the chain.
Setting the Output Volume
1.
Press <FUNCTION> repeatedly until VOLUME OUT is displayed.
2.
Select the desired output volume (1-100 % or non-stop) with <UP> or <DOWN>.
3.
Press <VOLUME> to confirm.
4.
Press <VOLUME> again to trigger the smoke at the set output.
The smoke machine will memorize the set output after switch-off. To reset
Activating the Fluid Sensor
The integrated fluid sensor measures the fluid level in the tank. To activate the fluid sensor:
1.
Press <FUNCTION> repeatedly until FLUID SENSOR is displayed.
2.
Select ON with <UP> or <DOWN>.
3.
Select OFF with <UP> or <DOWN> to deactivate the fluid sensor.
Timer Mode
In timer mode, the smoke machine will output smoke in pre-configured time intervals (see Timer Mode
Parameters below).
1.
Press <TIMER> until a timer is displayed.
2.
The smoke machine starts outputting smoke when the counter reaches zero (0).
3.
Set the timer duration in the DURATION SET menu option; set the output volume in the TIMER OUT
menu option.
4.
The cycle repeats itself until you press <TIMER> again or until the smoke machine runs out of
fluid.
Manual Mode
In manual mode, the smoke machine will output smoke for as long as the button remains pressed. The
output volume will be at 100 % output volume.
1.
Keep <MANUAL> pressed to output smoke.
2.
Release <MANUAL> to stop the smoke output.
V. 01 – 06/01/2016
HQSM10006
do not overlap.
the smoke output, repeat the steps above.
8