General Information - Novy Cloud 230 Instructions D'installation

Masquer les pouces Voir aussi pour Cloud 230:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

GENERAL INFORMATION

General
These are the mounting instructions for the Novy unit shown on the cover. The user manual is delivered separately with
this unit. Carefully read these instructions before installing and commissioning this unit. It is recommended to have one
or more qualified persons carry out the installation.
This manual makes use of a number of symbols. The meaning of these symbols are given below.
Symbol
Meaning
Indication
Warning
Safety
Observe the following mounting and safety tips for mounting:
• The installation and electrical connection of the unit shall be carried out by an authorised expert.
• The manufacturer does not accept any responsibility for any damage resulting from faulty building in or connection.
• Carefully take the unit from the packaging and check it for damage before mounting. Do not mount the unit in case of
any damage.
• Do NOT immediately remove the hood from the packaging. Place the box on the table top at the place where the hood
is to be mounted. Take notice of the description on the packaging and open this on the correct side for easy mounting.
• Check if all mounting materials have been supplied using the drawings in section 2.2.
• The unit is intended for household use only (preparation of food) excluding any other domestic, commercial or indus-
trial use.
• Position the electrical connection such, that it is located in the cabinet in which the cooking unit is mounted
• Safety can only be guaranteed if the unit is connected to an earth wire in accordance with the required regulations.
• Do not use an extension cord for connecting to the electricity grid.
Important before mounting
Page 2 of these mounting instructions show the mounting drawings. Observe the following mounting tips before starting
the mounting activities:
• For easier mounting of the ceiling unit, it is recommended to do this with at least 2 persons.
• Make sure that the ceiling has sufficient load bearing capacity.
• Position the wall socket in such a way that it is behind the ceiling unit.
• The bigger the distance between the hood and the hob, the less easily the cooking vapours will be absorbed by the
hood. Therefore, respect the (recommended) mounting height.
• In order to ensure that the cooking vapours are optimally absorbed, the hood (construction) must cover the entire cook-
ing surface. Centre the hood above the hob for optimum performance.
• For optimal performance, the hob must be larger than the exhaust hood (construction).
InTouch
InTouch offers the option to control the Novy cooker hood from the Novy InTouch induction hotplate. The hood may, as
a default, be combined with InTouch induction hotplates. Visit the website for the different models of induction hotplates
with InTouch.
INSTALLATION
Follow the mounting drawings on page 2.
1.
Do NOT immediately remove the hood from the packaging. Place the box on the table top at the place where
the hood is to be mounted. Take notice of the description on the packaging and open this on the correct side for
easy mounting.
• Indicate the middle point of the hood. The middle point must be above the centre of the hood
• Draw the centre line in the longitudinal direction.
The mounting height for a gas or induction cooking plate is min. 650 mm and max. 1600 mm.
Because of the substantial own weight of the hood, the ceiling must have sufficient load bearing capacity.
Action
Explanation of an indication on the hood
This symbol indicates an important tip or a dangerous situation.
EN 11