Limiting height adjustability
These settings could limit the desktop
movement range (should there be a rolling
file cabinet under the desk or a set of
shelves above it).
The stopping positions for the rolling file
cabinet become the new bottommost end
position, the shelf stopping position and the
new topmost end position.
Use the "Up" or "Down" button to move
the desktop to the lower halve or the upper
halve of the movement range.
Simultaneously press and hold the "Up" and
"Down" buttons for 10 seconds.
The position is being saved.
=
Resetting to factory settings
This function can be used to reset the DM
system to its factory settings.
Briefly press the buttons shown below
simultaneously:
a
"Down" button
b
"Up" button
Simultaneously press and hold the buttons
shown below until the red lamp goes out at
the signal lamp:
a
"Down" button
b
"Up" button
Wait until the signal lamp starts to rapidly
flash green; then press and hold the
"Down" button until the desktop has
reached the lowermost "Block" position.
There is a sound that will fade away (the
=
generated scratching noise is normal and
presents no sign of damage).
The DM system has been reset to its factory
=
settings.
Memory
5.2.4
control panel
Four different memory positions can be entered via
the Memory control panel.
153310
Operating and adjusting
Fig. 5-3: Memory control panel version
ATTENTION
Risk of damage to control panel!
Do not lean on the control
panel.
Do not place any objects on the
control panel.
Do not pour liquids over the
control panel.
Height adjustment – Memory control panel
Press the respective "Up or Down" button
to reach the desired desktop height.
The desktop moves up or down.
=
Release the "Up or Down" button.
The desktop stops at the desired point. The
=
display indicates the desktop height.
Manual desktop reset
Wait for 5 seconds if the desk has just been
connected to the mains.
Press and hold the "Down" button until the
lower end position is reached.
Continue to hold the "Down" button for at
least 3 seconds.
The resetting and initialisation process is
=
starting.
After conclusion of the resetting and
initialisation process, press the "Up" button.
The desired height is reached.
=
If the control panel is released before the
process is completed, the manual
resetting process will be interrupted and
must be restarted.
EN