schmalz SCTSi IOL Notice D'utilisation page 68

Table des Matières

Publicité

IO-Link Data Dictionary
21.10.01.00077/05
146
0x0092
10
Condition Monitoring ejector #10
146
0x0092
11
Condition Monitoring ejector #11
146
0x0092
12
Condition Monitoring ejector #12
146
0x0092
13
Condition Monitoring ejector #13
146
0x0092
14
Condition Monitoring ejector #14
146
0x0092
15
Condition Monitoring ejector #15
146
0x0092
16
Condition Monitoring ejector #16
146
0x0092
17
Condition Monitoring of Control-Unit
Event Codes of IO-Link Events and ISDU 138 (Extended Device Status)
Event code
Event name
Control-Unit
0x5100
General power supply fault
0x5110
Primary supply voltage over-run
0x5112
Secondary supply voltage fault
0x1812
Secondary supply voltage over-run
Supply pressure fault
0x1802
0x1811
Data Corruption
0x1000
General malfunction
Vacuum calibration OK
0x1800
0x1801
Vacuum calibration failed
0x8C01
Simulation active
0x180C
Primary supply voltage out of optimal range
0x180D
Secondary supply voltage out of optimal range
0x180E
Supply pressure out of optimal range
Ejectors
0x8D00
Measurement range overrun, Ejector #1
...
0x8D0F
Measurement range overrun, Ejector #16
0x8D10
Valve protection active, Ejector #1
...
0x8D1F
Valve protection active, Ejector #16
0x8D20
Evacuation time t1 is greater than limit, Ejector #1
...
0x8D2F
Evacuation time t1 is greater than limit, Ejector #16
0x8D30
Leakage rate is greater than limit, Ejector #1
...
0x8D3F
Leakage rate is greater than limit, Ejector #16
0x8D40
H1 was not reached, Ejector #1
...
0x8D4F
H1 was not reached, Ejector #16
0x8D50
Free-flow vacuum level too high, Ejector #1
...
0x8D5F
Free-flow vacuum level too high, Ejector #16
J. Schmalz GmbH
1byte
0-99
ro
1byte
0-99
ro
1byte
0-99
ro
1byte
0-99
ro
1byte
0-99
ro
1byte
0-99
ro
1byte
0-99
ro
1byte
0-99
ro
IO-Link Event Type
Extended Device Status Category
Error
Critical condiction, high
Warning
Critical condiction, high
Warning
Critical condiction, high
Warning
Critical condiction, high
Critical condiction, high
Warning
Error
Defect/fault, high
Error
Defect/fault, high
-
Notification
Notification
-
Warning
Warning, low
Warning
Warning, high
Warning
Warning, high
Warning
Warning, high
Error
Defect/fault, low
Error
Defect/fault, low
Warning
Warning, high
Warning
Warning, high
Warning
Warning, low
Warning
Warning, low
Warning
Warning, low
Warning
Warning, low
Warning
Warning, high
Warning
Warning, high
Warning
Warning, low
Warning
Warning, low
J. Schmalz GmbH
Johannes-Schmalz-Str.1
D 72293 Glatten
Tel.: +49(0)7443/2403-0
Fax: +49(0)7443/2403-259
schmalz@schmalz.de
Bit 4 = Free flow vacuum too high
Bit 5 = Manual Mode Active
0
0
0
0
0
0
0
Bit 0 = Primary Voltage limit
0
Bit 1 = Secondary voltage limit
Bit 2 = Input pressure limit (3,5 ... 5bar)
Remark
Primary supply voltage (US) too low
Primary supply voltage (US) too high
Secondary supply voltage (UA) too low
Secondary supply voltage (UA) too high
Input pressure too high or too low
Internal error, user data corrupted
Internal error, Bus fault
Calibration offset 0 set successfully
Sensor value too high or too low, offset not changed
Manual mode is active in at least one ejector
Condition Monitoring: primary supply voltage US outside of operating range
Condition Monitoring: secondary supply voltage outside of operating range
Condition Monitoring: supply pressure outside of operating range
Vacuum value > 999 mbar in Ejector #1
Vacuum value > 999 mbar in Ejector #16
SCTSi series
26.09.2020
SCTSi Data Dictionary