schmalz SCTSi IOL Notice D'utilisation page 64

Table des Matières

Publicité

IO-Link Data Dictionary
21.10.01.00077/05
242
0x00F2
0
Equipment identification
246
0x00F6
0
Geolocation
247
0x00F7
0
IODD Web Link
248
0x00F8
0
NFC Web Link
249
0x00F9
0
Storage location
253
0x00FD
0
Installation Date
Parameter
Device Settings
Commands
2
0x0002
System command
Access Control
90
0x005A
0
Extended device locks
91
0x005B
0
PIN code
Initial Settings
110
0x006E
1...16
Blow-mode for ejectors #1-#16
Process Settings
100
0x0064
1...16
Setpoint H1 for ejectors #1-#16
101
0x0065
1...16
Hysteresis h1 for ejectors #1-#16
102
0x0066
1...16
Setpoint H2 for ejectors #1-#16
103
0x0067
1...16
Hysteresis h2 for ejectors #1-#16
106
0x006A
1...16
Duration automatic blow for ejectors #1 - #16
107
0x006B
1...16
Permissible evacuation time for ejectors #1 - #16
108
0x006C
1...16
Permissible leakage rate for ejectors #1 - #16
Control-mode for ejector #1 - #16
109
0x006D
1...16
Observation
Monitoring
Process Data
40
0x0028
0
Process Data In Copy
41
0x0029
0
Process Data Out Copy
66
0x0042
0
Primary supply voltage
66
0x0042
1
Primary supply voltage, live
66
0x0042
2
Primary supply voltage, min
66
0x0042
3
Primary supply voltage, max
67
0x0043
0
Auxiliary supply voltage
67
0x0043
1
Auxiliary supply voltage, live
Auxiliary supply voltage, min
67
0x0043
2
Auxiliary supply voltage, max
67
0x0043
3
Evacuation time t0
148
0x0094
0
Evacuation time t0 for ejector #1
148
0x0094
1
Evacuation time t0 for ejector #2
148
0x0094
2
148
0x0094
3
Evacuation time t0 for ejector #3
148
0x0094
4
Evacuation time t0 for ejector #4
148
0x0094
5
Evacuation time t0 for ejector #5
148
0x0094
6
Evacuation time t0 for ejector #6
148
0x0094
7
Evacuation time t0 for ejector #7
148
0x0094
8
Evacuation time t0 for ejector #8
148
0x0094
9
Evacuation time t0 for ejector #9
148
0x0094
10
Evacuation time t0 for ejector #10
148
0x0094
11
Evacuation time t0 for ejector #11
148
0x0094
12
Evacuation time t0 for ejector #12
148
0x0094
13
Evacuation time t0 for ejector #13
Evacuation time t0 for ejector #14
148
0x0094
14
Evacuation time t0 for ejector #15
148
0x0094
15
Evacuation time t0 for ejector #16
148
0x0094
16
Evacuation time t1
149
0x0095
0
J. Schmalz GmbH
1...64 bytes
rw
1...64 bytes
rw
1...64 bytes
rw
1...64 bytes
rw
1...32 bytes
rw
1...16 bytes
rw
1 byte
5, 130, 165, 167, 168
wo
1 byte
0 - 3
rw
2 bytes
0-999
rw
16x 1 byte
0 - 2
rw
16x 2 bytes
998 >= H1 >= (H2+h1)
rw
16x 2 bytes
(H1-H2) >= h1 > 10
rw
16x 2 bytes
(H1-h1 >= H2 >= (h2+2)
rw
16x 2 bytes
(H2-2) >= h2 >= 10
rw
16x 2 bytes
0 - 9999
rw
16x 2 bytes
0 - 9999
rw
16x 2 bytes
0 - 999
rw
16x 1 byte
0 - 5
rw
see PD in
ro
see PD out
ro
6 bytes
ro
2 bytes
ro
2 bytes
ro
2 bytes
ro
6 bytes
ro
2 bytes
ro
2 bytes
ro
2 bytes
ro
32 bytes
ro
2 bytes
0 - 65.535
ro
2 bytes
0 - 65.535
ro
2 bytes
0 - 65.535
ro
2 bytes
0 - 65.535
ro
2 bytes
0 - 65.535
ro
2 bytes
0 - 65.535
ro
2 bytes
0 - 65.535
ro
2 bytes
0 - 65.535
ro
2 bytes
0 - 65.535
ro
2 bytes
0 - 65.535
ro
2 bytes
0 - 65.535
ro
2 bytes
0 - 65.535
ro
2 bytes
0 - 65.535
ro
2 bytes
0 - 65.535
ro
2 bytes
0 - 65.535
ro
2 bytes
0 - 65.535
ro
32 bytes
ro
J. Schmalz GmbH
Johannes-Schmalz-Str.1
D 72293 Glatten
Tel.: +49(0)7443/2403-0
Fax: +49(0)7443/2403-259
schmalz@schmalz.de
***
User string to store e.g. identification name from schematic
***
User string to store geolocation from handheld device
***
User string to store web link to IODD file
https://myproduct.schmalz.com/
Web Link to NFC App (base URL for NFC tag)
#/
***
User string to store storage location
***
User string to store date of installation
0x05 (dec 5): Force upload of parameter data into the master
0x82 (dec 130): Reset device parameters to factory defaults
0x82
0xA5 (dec 165): Calibrate vacuum sensor of all ejectors
0xA7 (dec 167): Reset erasable counters in all ejectors
0xA8 (dec 168): Reset voltage min/max
Bit 0: NFC write lock
Bit 1: NFC disable
0
Bit 2: local Firmware update (Firmware update locked)
Bit 3: local user interface locked (manual mode in ejectors locked)
Bit 4: IO-Link event lock (suppress sending io-link events)
0
Pass code for writing data from NFC app
Blow mode setting for each ejector
subindex corresponds to ejector number
subindex 0 for access to full array (16 bytes)
0
0x00 = Externally controlled blow-off
0x01 = Internally controlled blow-off – time-dependent
0x02 = Externally controlled blow-off – time-dependent
750
Unit: 1 mbar. Subindex corresponds to ejector number
150
Unit: 1 mbar. Subindex corresponds to ejector number
550
Unit: 1 mbar. Subindex corresponds to ejector number
10
Unit: 1 mbar. Subindex corresponds to ejector number
200
Unit: 1 ms. Subindex corresponds to ejector number
2000
Unit: 1 ms. Subindex corresponds to ejector number
250
Unit: 1 mbar/sec. Subindex corresponds to ejector number
Control mode settings for each ejector
Subindex corresponds to ejector number
subindex 0 for access to full array (16 bytes)
0x00 = control is not active, H1 in hysteresis mode
0x0002
0x01 = control is not active, H1 in comparator mode
0x02 = control is active
0x03 = control is active with supervision of leakage
0x04 = control is active, continuous succing disabled
0x05 = control is active with supervision of leakage, continuous succing disabled
-
Copy of currently active process data input (length see above)
-
Copy of currently active process data output (length see above)
-
subindex 0 for access to all primary supply voltage values
-
Primary supply voltage (US) as measured by the device (unit: 0.1 Volt)
-
min. value of primary supply voltage (unit: 0.1 Volt) - rest by ISDU 0x0002
-
max. value of primary supply voltage (unit: 0.1 Volt) - rest by ISDU 0x0002
-
subindex 0 for access to all auxiliary supply voltage values
-
Auxiliary supply voltage (UA) as measured by the device (unit: 0.1 Volt)
min. value of auxiliary supply voltage (unit: 0.1 Volt) - rest by ISDU 0x0002
-
max. value of auxiliary supply voltage (unit: 0.1 Volt) - rest by ISDU 0x0002
-
subindex 0 for access to all ejectors
0
0
0
0
0
0
0
0
Time from start of suction to H2 (unit: 1 ms)
0
0
0
0
0
0
0
0
subindex 0 for access to all ejectors
SCTSi series
26.09.2020
SCTSi Data Dictionary

Publicité

Table des Matières
loading

Table des Matières