schmalz SCTSi IOL Notice D'utilisation page 63

Table des Matières

Publicité

IO-Link Data Dictionary
21.10.01.00077/05
Air saving function (H1) Ejector #15
Part present (H2) Ejector #15
Air saving function (H1) Ejector #16
Part present (H2) Ejector #16
Process Data Out
Device-Select
PD Out Byte 0
-
EPC-Select 0
EPC-Select 1
PD Out Byte 1
Input pressure
Vacuum Ejector #1
Blow-off Ejector #1
Vacuum Ejector #2
Blow-off Ejector #2
PD Out Byte 2
Vacuum Ejector #3
Blow-off Ejector #3
Vacuum Ejector #4
Blow-off Ejector #4
Vacuum Ejector #5
Blow-off Ejector #5
Vacuum Ejector #6
PD Out Byte 3
Blow-off Ejector #6
(if available - see PD Out length)
Vacuum Ejector #7
(for up to 8 ejectors)
Blow-off Ejector #7
Vacuum Ejector #8
Blow-off Ejector #8
Vacuum Ejector #9
Blow-off Ejector #9
Vacuum Ejector #10
PD Out Byte 4
Blow-off Ejector #10
(if available - see PD Out length)
Vacuum Ejector #11
(for up to 12 ejectors)
Blow-off Ejector #11
Vacuum Ejector #12
Blow-off Ejector #12
Vacuum Ejector #13
Blow-off Ejector #13
Vacuum Ejector #14
PD Out Byte 5
Blow-off Ejector #14
(if available - see PD Out length)
(for up to 16 ejectors)
Vacuum Ejector #15
Blow-off Ejector #15
Vacuum Ejector #16
Blow-off Ejector #16
ISDU Parameters
ISDU Index
Subindex
dec
hex
dec
Identification
Device Management
16
0x0010
0
Vendor name
17
0x0011
0
Vendor text
18
0x0012
0
Product name
19
0x0013
0
Product ID
20
0x0014
0
Product text
21
0x0015
0
Serial number
22
0x0016
0
Hardware revision
23
0x0017
0
Firmware revision
240
0x00F0
0
Unique ID
241
0x00F1
0
Device type and features
Article number
250
0x00FA
0
Article revision
251
0x00FB
0
Production date
252
0x00FC
0
Product text (detailed)
254
0x00FE
0
Product Configuration (detailed)
354
0x0162
0
Device Localization
Application specific tag
24
0x0018
0
J. Schmalz GmbH
4
5
6
7
Name
Bit
4 ... 0
5
6
7
7...0
0
1
2
3
4
5
6
7
0
1
2
3
4
5
6
7
0
1
2
3
4
5
6
7
0
1
2
3
4
5
6
7
Parameter
Data width
15 bytes
15 bytes
32 bytes
1...32 bytes
30 bytes
9 bytes
2 bytes
4 bytes
20 bytes
11 bytes
14 bytes
2 bytes
10 bytes
1....64 bytes
1....67 bytes
1 ... 32 bytes
ro
ro
ro
ro
Access
wo
wo
wo
wo
wo
wo
wo
wo
wo
wo
wo
wo
wo
wo
wo
wo
wo
wo
wo
wo
wo
wo
wo
wo
wo
wo
wo
wo
wo
wo
wo
wo
wo
wo
wo
wo
wo
Value range
Access
Default value
ro
J. Schmalz GmbH
ro
www.schmalz.com
ro
SCTSi-IOL
ro
SCTSi-IOL
ro
SCTSi-IOL
ro
000000001
ro
04
ro
1.07
ro
ro
ro
10.02.02.*
ro
00
ro
G16
ro
SCTSi-IOL-14-AB-4D01...
ro
D00-D01-D02-D03-D04...
rw
***
J. Schmalz GmbH
Johannes-Schmalz-Str.1
D 72293 Glatten
Tel.: +49(0)7443/2403-0
Fax: +49(0)7443/2403-259
schmalz@schmalz.de
Vacuum is over H1 & not yet under H1-h1
Vacuum is over H2 & not yet under H2-h2
Vacuum is over H1 & not yet under H1-h1
Vacuum is over H2 & not yet under H2-h2
Remark
number of device which will send EPC Data
0:
Contol-Unit
1 ... 16:
number of SCPS ejector
17 ... 31: reserved
reserved
function of EPC values 1 and 2 (see PD In Byte 1...3) for selected device
Pressure value from external sensor (unit: 0.1 bar)
Vacuum on/off
Activate Blow-off
Vacuum on/off
Activate Blow-off
Vacuum on/off
Activate Blow-off
Vacuum on/off
Activate Blow-off
Vacuum on/off
Activate Blow-off
Vacuum on/off
Activate Blow-off
Vacuum on/off
Activate Blow-off
Vacuum on/off
Activate Blow-off
Vacuum on/off
Activate Blow-off
Vacuum on/off
Activate Blow-off
Vacuum on/off
Activate Blow-off
Vacuum on/off
Activate Blow-off
Vacuum on/off
Activate Blow-off
Vacuum on/off
Activate Blow-off
Vacuum on/off
Activate Blow-off
Vacuum on/off
Activate Blow-off
Remark
Manufacturer designation
Internet address
General product name
Product variant name
Order-Code (partial); for complete Order-Code read Index 0xFE
Serial number
Hardware revison
Firmware revision
unique device identification number
type code of device features
Order-Nr.
Article revision
Date of production
Detailed type description of the device
Detailed configuration of the device
Asset-ID
SCTSi series
26.09.2020
SCTSi Data Dictionary

Publicité

Table des Matières
loading

Table des Matières