30. Do not abuse cord. Never yank cord to discon-
nect it from the receptacle. Keep cord away from
heat, oil, water and sharp objects.
31. NEVER stack workpieces on the table top to
speed cutting operations. Cut only one piece at a
time.
32. Some material contains chemicals which may be
toxic. Take caution to prevent dust inhalation
and skin contact. Follow material supplier safety
data.
SAVE THESE INSTRUCTIONS
WARNING:
MISUSE or failure to follow the safety
rules stated in this instruction manual
may cause serious personal injury.
INSTALLATION
Bench mounting
When the tool is shipped, the handle is locked in the low-
ered position by the stopper pin. Release the stopper pin
by lowering the handle slightly and pulling the stopper
pin.
1
This tool should be bolted with two bolts to a level and
stable surface using the bolt holes provided in the tool's
base. This will help prevent tipping and possible injury.
1
003923
1. Stopper pin
003924
1. Bolt
Turn the adjusting bolt clockwise or counterclockwise so
that it comes into a contact with the floor surface to keep
the tool stable.
1
FUNCTIONAL DESCRIPTION
CAUTION:
•
Always be sure that the tool is switched off and
unplugged before adjusting or checking function on
the tool.
Blade guard
When lowering the handle, the blade guard rises auto-
matically. The guard is spring loaded so it returns to its
original position when the cut is completed and the han-
dle is raised. NEVER DEFEAT OR REMOVE THE
BLADE GUARD OR THE SPRING WHICH ATTACHES
TO THE GUARD.
In the interest of your personal safety, always maintain
the blade guard in good condition. Any irregular opera-
tion of the blade guard should be corrected immediately.
Check to assure spring loaded return action of guard.
NEVER USE THE TOOL IF THE BLADE GUARD OR
SPRING ARE DAMAGED, FAULTY OR REMOVED.
DOING SO IS HIGHLY DANGEROUS AND CAN
CAUSE SERIOUS PERSONAL INJURY.
If the see-through blade guard becomes dirty, or sawdust
adheres to it in such a way that the blade is no longer
easily visible, unplug the saw and clean the guard care-
fully with a damp cloth. Do not use solvents or any petro-
leum-based cleaners on the plastic guard.
If the blade guard is especially dirty and vision through
the guard is impaired, use the supplied socket wrench to
loosen the hex bolt holding the center cover. Loosen the
hex bolt by turning it counterclockwise and raise the
blade guard and center cover. With the blade guard so
positioned, cleaning can be more completely and effi-
ciently accomplished. When cleaning is complete,
5
003925
1. Adjusting bolt
002252
1. Blade guard
1