2.3. PIPING AND VALVES
RAMSES
A
B
C
D
1
2 3
4
5
A
B
C
D
180 mm 180 mm 130 mm 280 mm
1. SKIMMER (Ø50)
2. MAIN DRAIN (Ø50)
To connect the piping, glue it to the fittings supplied with the pump: the fittings to the pump's
suction and return inlets are threaded and come with watertight seals to prevent leaking.
Ensure the return pipes are fitted completely perpendicular to and perfectly aligned with the inlet
to be connected to prevent the pump and the piping being subject to external forces, which besides
making assembly difficult could even break them.
Fit the suction pipes slightly inclined towards the pump (2%) to prevent pockets of air from forming.
For the pump to work properly, prime the pump's prefilter until the water flows out of the suction
conduit.
To prevent damage during shipping, the filtration housing is disconnected from the pump's waste
water pipe. It must be glued before proceeding with its external connection
6
RAMSES UP
A B
C
D
1 2 3
4
5
A
B
C
D
132 mm 132 mm 295 mm 205 mm
IN
3. SUCTION INLET (Ø50)
KEOPS
A B
C
D
1 2 3
4 5
A
B
C
D
132 mm 132 mm 282 mm 164 mm
4. WASTE WATER PIPE (Ø50)
COMPACT FILTRATION HOUSING -
INSTRUCTION AND MAINTENANCE MANUAL
KEFREN
A B
C
D
1 2 3 4
5
A
B
C
D
132 mm 132 mm 132 mm 428 mm
OUT
5. RETURN TO POOL (Ø50)