13. Setting the hygiene flush

The hygiene flush can be adjusted with an ECC2 function controller via the web
application.

14. Maintenance and care

The fitting must be checked and maintained at regular intervals, depending on the
water quality and in accordance with the local conditions and rules and regulations
applicable at the site.
Use suitable cleaning agents which do not attack the fitting in a proper manner and
rinse with water after use. High-pressure cleaners must not be used for cleaning.

15. Troubleshooting

Fault
Water does not flow
Water flows
continuously
If you cannot rectify a fault or if it is not in the list, please contact our customer
service department!

16. Spare parts

Description
1 Cover plate complete . . . . . . . . . . 2000109488
2 Sensor. . . . . . . . . . . . . . . . . . . . . . 2000105815
3 Motor. . . . . . . . . . . . . . . . . . . . . . . 2030022899
4 Electronic module* . . . . . . . . . . . . 84-100-17.109
5 Electrical T-distributor . . . . . . . . . . 2000100853
* When ordering please specify the fitting ID!
The fitting ID can be found on the side of the
electronic module.
8
Cause
– Water supply interrupted
– Angle valve closed
– Electronics module faulty
– Motor faulty
Order No.
Remedy
➯ Restore it
➯ Open it
➯ Replace it
➯ Replace it
Accessories
Function controller with
Ethernet and CAN Bus connector (60 W)
ECC2 . . . . . . . . . . . . . . . . . . . . 2000108123
System cable for long-term use in water,
halogen-free 100 m . . . . . . . . . 2000104272
halogen-free 25 m . . . . . . . . . . 2000104274
System cable,
not halogen-free 100 m . . . . . . 2000100801
not halogen-free 25 m . . . . . . . 2000100852
Order No.

Publicité