III - INSPECTION BEFORE USE
N.B.!
-
If using the generator for the first time the tank must have at least 2 litres of fuel.
-
The generator must always be inspected prior to being used
III-1 – Check the fuel level
 Ensure that there is enough fuel in the tank
 If there is too little fuel then fill it with lead free petrol; ensure that the filter is always in
the tank opening when filling, see fig.
 The content of the fuel tank is 5.1 litres.
Warning!
 Never fill the tank when the engine is running or still
hot.
 Close the fuel cock before filling the tank.
 Keep the fuel free of dust, dirt, water or other
materials/objects.
 Do not fill the tank past the filter; when the fuel heats
up it expands.
 Close the tank cap properly after filling.
 Wipe up any spilled fuel before starting the engine.
 Keep the generator and fuel away from open flames.
III-1 – Check the oil level
Check that the oil level is filled to maximum in the oil
reservoir. Top up oil if necessary.
 Remove the cap with the dip stick and check the oil
level
 If the oil level is below the minimum level, top it up to
the maximum level. Do not screw the cap on when
checking the oil level.
 Change the oil if it is dirty.
 Contents oil reservoir: 0.9 litres
 Recommended oil: API Service "SJ" or above, see
table.
III-3 – Earthing
Equip the generator with a properly connected, properly
functioning earth wire.