CONTROL PANEL NE274-S
GB
CONTROLS:
Push button with warning light for turning
INTERNAL LIGHTS on or off
Push button with warning light for turning
EXTERNAL LIGHTS on or off
SCREENS:
The warning light goes on when the 230V mains is connected
The warning light goes on when
of the 230V mains when the two batteries are in parallel verifing before the battery service voltage
Press the push button to see internal temperature on the display (
temperature (
If the temperature probe is faulty the wording "
The screen remains active for approx. 30 seconds.
Repeatedly pressing this Key for viewing the level percentage % (0, 25, 50, 75, 100) of tank S1 and the level
percentage % (0, 100) of tank recovery R1, R2
If S1 is empty or R1, R2 is full, the display flashes.
If the tank is wrongly connected, the display will show "
The screen remains active for approx. 30 seconds.
Press the push button once to see the voltage on the service battery (B2)
again to see the voltage on the
remaining battery B2 and press the push button again to see displays the % the remaining battery B1.
Only in the view as %, if there is
segments to indicate the battery charge.
The screen remains active for approx. 30 seconds.
ALARMS:
Batteries: Car battery (B1) less than 11,8V or Service battery (B2) less than 10V.
In this case there is a bleep (if enabled) and the flashing battery symbol that have generated the alarm (for the first
30 seconds you see the value)
Hold for more than 3 seconds (
batteries alarm
Tanks:
Tank S1 empty or Recovery tanks R1,R2 full.
In this case there is a bleep (if enabled) and the flashing symbol the corresponding tank that raised the alarm
(for the first 30 seconds you see the value)
Hold for more than 3 seconds (
tanks
Beep:
Hold for more than 3 seconds (
confirmation beep button pressed, and alarm buzzers
:
This symbol appears when there is an error communicating with NE185 shunt.
CONSUMPTION:
To turn on the control panel you must touch for 1 sec. the right or left side panel where there are the keys.
On stand by (no active controls) the control panel with shunt NE185/NE196 consumes a total of approx 40mA. When the key
(
) is pressed the control panel turns itself off and total consumption is reduced to just 3mA.
If the service battery voltage drops below 10V, after 1 minute the control panel turns itself off, together with all live parts.
In this case is advisable to disconnect all loads with the battery main switch and recharge the battery services within 2 days.
WARNING: If the vehicle not in use and the connection 230V is not present, disconnect the battery service with the battery
main switch.
CONNECTIONS:
The back of the panel has a connector for serial connection (JP8), a connector for the optional external temperature probe
(JP3) and a connector for the optional remote internal temperature probe (JP4).
If connecting the remote internal temperature probe must be cut and remove the temperature sensor of the pc-board
positioned between the support and the frame.
the vehicle engine is running and the parallel batteries is active or in the presence
). If you get the message "
starter battery (B1)
or
) button can be disabled (show "
) button can be disabled (show "
) button can be disabled (show "
Push button with warning light for turning
PUMP on or off
Push button with warning light for turning
AUX on or off
), press the push button twice to view external
", the temperature sensor is not present.
" will appear
".
.
Press the push button again to see displays the % the
the displayed value of the select battery is replaced with the moving
4
, Press the push button
") or enabled (show "
") or enabled (show "
") the alarm of all
") or enabled (show "
") the the
GB
") the low