Candy PL2D40NX Notice D'emploi page 21

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 8
Adapting the hob to different types of gas
To adapt the Hob for use with different types of gas, carry out the following instructions:
— remove the grids and burners
— insert the hexagonal spanner (supplied) into the burner support (Fig. 5)
— unscrew the injector and replace it with one suitable for the gas to be used (see
Table of gas consumption)
— carry out regulation of the burner.
Table of gas consumption
G20/G25
G30
G20/G30
Working
Ø injector
Ø injector
Qn
l/h
burner
1/100 mm
1/100 mm
kW
G20
large back right
120
80
2,65
252
large front left
127
84
2,95
281
medium
93
61
1,5
143
small
80
54
1,1
105
double ring
2x94
2x65
3,3
314
maxi
2x94
2x65
3,3
314
Hexagonal spanner
Regulating the burners
For maximum efficiency from the burners, the correct combustion of the flame is neces-
sary (see table of gas consumptions quota "X"). A good flame must be well aligned and
without yellow tips (Fig. 7/B). If there is insufficient air, the flame will be uneven with yel-
low tips (Fig. 7/A). If there is too much air, the flame will be very short and bright (Fig.
7/C). In these cases the combustion
must be adjusted by re-fitting the carburation tube to the Venturi (where there is insuffi-
cient air) or removing the carburation tube (in the case of too much air). To position the
carburation tube, the fixing screws must be loosened, and retightened when the sati-
sfactory combustion is obtained.
Quota «X» depending
1W = 0,860 kcal/h
on type of gas
G25
G20
G30
g/h
g/h
Qn
l/h
Qmin.
air
air
G30
G31
kW
G25
kW
regul.
regul.
193
189
2,5
277
0,650
4 mm
2 mm
215
211
2,8
310
0,650
4 mm
2 mm
109
107
1,45
161
0,380
2 mm
5 mm
80
79
1,05
116
0,280
6 mm
4 mm
238
236
3,1
314
0,900
13 mm
0 mm
238
236
3,1
314
0,900
13 mm
0 mm
Fig. 5
38
For dimensions «X» see table of gas consumption
BURNER
BURNER CAP
Regulating the minimum flame
G25
G31
air
air
After lighting the burners, turn the control knob to the minimum setting and then remo-
regul.
regul.
ve the knob (this can easily be removed by apply a gentle pressure).
4 mm
5 mm
Using a small «Terminal» type screwdriver the regulating screw can be adjusted as in
4 mm
5 mm
Fig. 8. Turning the screw clockwise reduces the gas flow, whilst turning it anticlockwise
2 mm
7 mm
increases the flow – Use this adjustment to obtain a flame of approximately 3 to 4 mm
6 mm
6 mm
in length and then replace the control knob.
15 mm
15 mm
If GPL (cylinder) gas is being used, turn the screw clockwise right to the end of the
13 mm
13 mm
travel of the by-pass.
Screws regulating
Fig. 8
When you have carried out the new gas regulation, replace the old gas rating pla-
te on your appliance with one (supplied with hob) suitable for the type of gas for
which it has been regulated.
SMALL
MEDIUM
LARGE
FIXING
SCREW
AIR REGULATION
SCREW
DOUBLE RING
Fig. 6
MAXI
(for differend models)
39
Fig. 7

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Pl2d40w

Table des Matières