8. CLEARING THE REMOTE CONTROLS
AND ALL SETTINGS
8.1. Clearing the settings - Fig. 23
Attention
If the settings are deleted, they are reset to the factory values. It is
important to set the barrier opening direction again and to calibrate
the electronic end limits.
1) Select
in the control unit menu.
2) Press OK on the control unit to confirm the factory configuration reset
of the control unit.
8.2. Clearing the memorised remote controls - Fig 24
Press the PROG button on the control unit for 7 seconds.
The indicator light flashes slowly; all remote controls have been cleared.

9. DIAGNOSTIC AND TROUBLESHOOTING

9.1. Diagnostics
Code
Description
Activation of the external
radio start input
Activation of the OPEN input
Activation of the CLOSE input
Activation of the TIMER input
Activation of the STOP input
Activation of the PHOT
photoelectric cells input or,
if configured as active cells
with auto-test, activation of
the associated FAULT input
Activation of the safety edge
input or, if configured as
safety edge with auto-test,
activation of the associated
FAULT input
Activation of the motor
closing end limit input
Activation of the motor
opening end limit input
Photoelectric cell auto-test
failure
Safety edge auto-test failure Check connection and/or
Circuit board equipment test
*
error
*
Encoder error
*
Obstacle detection
*
Thermal
Copyright
©
2017 SOMFY ACTIVITES SA. All rights reserved.
Comments
Check connection and/or
settings.
settings.
Check connections on the
motor.
Equipment problems on the
circuit board; contact Somfy.
Check the wiring and the en-
coder circuit board, possibly
the direction of the motor
and reset the circuit board to
factory configuration.
Check the presence of an
obstacle.
With until the mechanism
cools down.
Code
Description
System supervision internal
control error
Control unit settings co-
herence error (
)
Error in the D-track settings
*
End limit error
*
= 0, 1, ....., 9, A, B, C, D, E, F

10. TECHNICAL DATA

Power supply
220-230 Vac 50/60 Hz
Motor voltage
24 Vdc
Power consumption
300 W
Maximum torque
130 Nm (Levixo 40) / 260 Nm (Levixo 60)
End limit
Mechanical and electrical setting
Obstacle detection
Encoder (optical)
Unlocking
Individual key
Speed
2.5 s to 6 s (Levixo 40) / 3 s to 9 s (Le-
vixo 60)
Maximum boom length
4 m without accessories (Levixo 40) / 6 m
without accessories (Levixo 60)
Climatic operating con-
- 20°C/+ 55°C - IP 54
ditions
Use - maximum number
Intensive - 85 cycles / hour (approx. 2,000
of cycles
cycles/day)
Weight (without boom)
40 kg
Control unit
Protection against surges
So ware
and short-circuiting
Fuses F1 (2 A), F3 (1.25 A T), F4 (1.25 A T)
- Fig.16
Accessories power supply 24 V (maximum intensity 0.5 A)
24 V (auto-test)
AUX 0
Contact powered NO (max. 24 V / 1 A)
AUX 3
Contact NO (max. 24 V / 1 A)
Radio frequency
Number of channels that
128
can be memorised
Programming interface
LCD screen - 4 buttons
Comments
Try to switch the circuit board
off and on again. If the prob-
lem persists, contact Somfy.
Pressing OK once will confirm
and
the settings detected. The
board will continue to work
with the settings detected.
Attention
Check the settings (
et
).
A er pressing OK, the board
will continue to operate with
D-track by default.
Attention
Auto-configuration is
required.
Check the wiring of the end
limits.
Barrier
433.42 MHz
< 10 mW
EN
9

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

1216589

Table des Matières