Product Description - SOMFY LEVIXO 40/60 24V RTS Manuel D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

EN
1.10. Regulations
Somfy declares that, when used in accordance with these in-
structions, the product described in these instructions complies
with the essential requirements of the applicable European direc-
tives, and in particular Machinery Directive 2006/42/EC and Radio
Equipment Directive 2014/53/EU.
The full text of the EC declaration of conformity is available at the
following website: www.somfy.com/ce.
Antoine CREZE, Head of Regulations, Cluses
1.11. Assistance
You may encounter difficulties or have questions when installing
your motorisation.
Do not hesitate to contact us; our specialists are on hand to an-
swer all your questions.
Internet: www.somfy.com

2. PRODUCT DESCRIPTION

2.1. Scope of application
This motorisation is intended exclusively for a barrier for residential and
collective use and for vehicles only.
Useful boom length
Boom accessories
Rubber under
the boom (ref.
9017045)
Rubber on the
boom (ref.
9017045)
LED lighting kit
(ref. 9020718)
Rest fork (ref.
9020720)
H3
Min. L
4.2 m 4.3 m 4.5 m 4.8 m 4.6 m 4.7 m 5 m 4.7 m
Max. L 5 m 5 m 5 m 5 m 5 m 5 m 5 m 6 m
H2
Min. L
2.6 m 3 m 3.2 m 3.4 m 3.3 m 3.4 m 3.6 m 4.1 m
Max. L 4 m 4.1 m 4.4 m 4.7 m 4.4 m 4.6 m 4.7 m 4.6 m
H3
Min. L
2.8 m 2.8 m 2.8 m 2.8 m 2.8 m 2.8 m 4 m 3.8 m
Max. L 4 m 4 m 4 m 4 m 4 m 4 m 4 m 4 m
H2
Min. L
2.2 m 2.3 m 2.5 m 2.6 m 2.6 m 2.6 m 2.6 m 2.9 m
Max. L 2.7 m 2.7 m 2.7 m 2.7 m 2.7 m 2.7 m 2.7 m 3.7 m
H1
Min. L
1.4 m 1.4 m 1.5 m 1.6 m 1.7 m 1.8 m 1.9 m 2.1 m
Max. L 2.2 m 2.3 m 2.5 m 2.6 m 2.6 m 2.7 m 2.7 m 3 m
H1
H2
H3
Le -sided mounting
4
H1
H2
H3
Right-sided mounting
2.2. Dimensions - Fig. 1
2.3. Standard installation - Fig. 2
No.
Description
1
Levixo 40/60 motor
2
Boom
3
Rest fork
4
Pillar for photoelectric cell
5
Orange light
6
Magnetic coil
3. INSTALLATION
Attention
Check that the ground is level.
The barrier can be installed either directly on the ground or using the
mounting plate provided (recommended for easier levelling).
The barrier is supplied for le -hand mounting.
3.1. Preparing the base
Attention
Before opening the door of the housing, it is essential to ensure that
the spring is released by moving the boom to the vertical position
as shown in figure 15.
The door of the housing must be facing inside the property.
3.1.1. Foundations with a base plate (optional) and con-
crete foundation - Fig. 3
1) Make a hole in the base suitable for the type of terrain.
2) Use several ducts to route the electrical cables.
3) Place the 4 bolts supplied with the base plate in the final position with
the thread of the bolt facing upwards and weld the heads of the 4 bolts
to the base. Protect the welds with an anti-rust product.
4) Position the plate so that it protrudes from the ground by approximate-
ly 20 mm.
In figure 3, the arrows indicate the direction in which the vehicles drive.
5) Fill the base with concrete, using a spirit level to check the position of
the plate in both directions, and leave the cement to harden.
3.1.2. Foundations without base plate - Fig. 4
1) Place the housing on the ground.
2) Unhook (Fig. 9) then remove the spring for easier access to the hous-
ing mounting holes.
3) Mark the mounting holes.
4) Remove the housing and drill the mounting holes.
5) Insert plugs (not provided) in the mounting holes.
The top surface of the actuator is angled slightly to prevent rain water
from collecting. Use a side surface to check that the housing is level.
3.2. Mounting the housing - Fig. 5
Secure the housing using M12 nuts.
The earth wire is not provided.
3.3. Mounting the boom - Fig. 6
1) Lubricate the sha before installing the boom mounting plate.
2) Place the end limit against its stop block in the vertical position ac-
cording to whether the barrier is mounted on the le -hand side (Fig.
7A) or right-hand side (Fig. 7B). Disengage if necessary (Fig. 15).
IMPORTANT: the spring must have been remove at this stage.
3) Place the mounting plate on the sha . It must be parallel to the housing.
LEVIXO 40/60 24V RTS
Cable (mm²)
2 x 1.5 + T
-
-
2 x 0.75 + 4 x 0.75
2 x 0.75
Cable provided with
the magnetic coil
ref. 9020724