SOMFY LEVIXO 40/60 24V RTS Manuel D'installation page 13

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

LEVIXO 40/60 24V RTS
4) Secure using the bolt provided in the mounting kit.
Tightening the bolt will drive the mounting plate down parallel.
5) Screw the calliper to the mounting plate, leaving enough play to facil-
itate assembly of the boom.
The calliper is fitted with stops allowing the boom to be blocked. Place
the stops towards the bottom.
6) Disengage the boom (Fig. 15) to turn the mounting plate and calliper to
the horizontal position and insert the boom.
7) Disengage again to place the boom in the vertical position. Once the
boom is fitted firmly onto its stop, tighten the 4 bolts.
8) Remove the protective film from the cover.
3.4. Setting the end limits
The barrier is fitted with adjustable electrical end limit contacts and a me-
chanical stop.
A rotation margin of approximately 1° must be le between the electrical
end limit contact and the mechanical stop, both for opening and closing, in
order to prevent damage to the end limit contacts.
Setting the mechanical end limits - Fig. 7
A
Fig. 7
: Le -sided mounting
B
Fig. 7
: Right-sided mounting
Key
FCC: Closing end limit
FCO: Opening end limit
In the open position (vertical boom), leave an additional 1° in order to
facilitate calibration of the electrical end limit.
3.5. Installing and setting the spring - Fig. 8
1) Open the barrier.
2) Install the spring connector on the le -hand or right-hand section of
the mechanical end limit according to the side on which the barrier is
to be installed.
A
Fig. 8
: Le -sided mounting
B
Fig. 8
: Right-sided mounting
The mechanical end limit has 3 mounting holes according to the de-
sired length of boom. Place the spring connector in the appropriate
hole for the installation (see "Useful boom length" in "2.1. Scope of
application").
3) Fasten the spring tensioner to the mechanical end limit in accordance
with the assembly diagram.
4) Fasten the spring to the tensioner.
5) Secure the spring to the lower section of the housing by sliding the
spring into the notch then turning the spring upwards slightly so that it
pushes against its stop.
3.6. Balancing the boom - Fig. 9
Attention
The boom must be balanced at 45°-50°.
Balance the boom by increasing the tension of the spring.
Attention
Once the boom is balanced, tighten the top and bottom nuts of the
tensioner so that the vibrations do not cause the nuts to move.
Otherwise, the spring will not remain in position and the boom will
not be correctly balanced.
Copyright
©
2017 SOMFY ACTIVITES SA. All rights reserved.
3.7. Electrical connection - Fig. 10
Warning
• Use a 3x1.5 mm² cable for use outside (min. type H07RN-F).
• The cable clamps supplied must be used.
• For all low-voltage cables, ensure that they can withstand trac-
tion of 100 N. Check that the conductors have not moved when
this traction is applied.
L
Brown
4. COMMISSIONING
4.1. Navigating the settings menu
Buttons
OK
• Press twice to access the settings menu
• Press once to confirm:
+ OR -
Navigating the parameter list
Modifying the value of a setting
+ AND -
Exiting the settings menu
4.2. Setting the opening direction of the barrier -
Fig. 11
The barrier is set for le -hand mounting as standard.
Change the opening direction of the barrier in the event of right-handing
mounting.
Menu
Sub-menu
Value
0
1
4.3. Calibrating the electronic end limits - Fig. 12
Calibration is required so that the mechanical end limit ends its travel gen-
tly on the mechanical stop.
Menu
Sub-menu
Value
0 to 100
(40)
0 to 100
(60)
4.4. Programming the remote controls - Fig. 13
1) Press the PROG button on the control unit for 2 seconds.
The indicator light is lit constantly.
2) Press the button on the remote control which will open the barrier.
The indicator light flashes; the remote control has been stored.
If this procedure is carried out using a channel which has already been
memorised, this channel will be cleared.
To exit programming mode without programming a remote control:
briefly press the PROG button on the control unit.
N
Blue
Yellow/Green
Function
- the parameter selection
- the parameter value
Description
Opening direction reversed in
relation to standard operation
(right-hand barrier)
Standard operation (le -hand
barrier)
Description
Calibrating the opening end limit
(%)
Calibrating the closing end limit
(%)
EN
5

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

1216589

Table des Matières