8
Val.
0
Cell safety input active without auto-test.
The cells are active at opening and closing. When closing, movement inverted if the cells are not
obscured.
1
Cell safety input active with auto-test.
The mechanism's auto-test is conducted at the start of the movement.
The cells are active at opening and closing. When closing, movement inverted if the cells are not
obscured.
2
Cell safety input active without auto-test.
The cells are active at opening and closing. When closing, movement inverted if the cells are not
obscured.
3
Unavailable
4
Cell safety input active without auto-test.
The cells are only active when closing. In the event of activation, movement inverted
when the cells are no longer blocked.
5
Cell safety input active with auto-test.
The cells are only active when closing. In the event of activation, movement inverted
when the cells are no longer blocked.
6
Safety edge safety input active without auto-test
In the event of activation, movement inverted for 2 s.
7
Safety edge safety input active with auto-test
The mechanism's auto-test is conducted at the start of the movement.
In the event of activation, movement inverted for 2 s.
0
Radio-configured input
Operation in accordance with STEP BY STEP movt rationale
1
Unavailable
2
Input configured as open
A command causes the barrier to open. If the input remains closed, the barrier remains open until
the contact is opened. With the contact open, the barrier closes a er the automatic closing timeout
if this is activated.
3
Input configured as closed
A command causes the barrier to close.
4
Unavailable
5
Input configured as timer
Identical operation to "Open" but closing is guaranteed even in the event of a power cut.
1
SCA barrier open indicator light output
Contact closed when opening and when the barrier is open, intermittent during closing, open with
barrier closed.
2
Courtesy lighting command output
Contact closed for 90 seconds a er the last movement
12
Barrier status output
Contact closed when the barrier is completely closed
Control unit reset to factory configuration
Default value
Control unit so ware version
Number of cycles (per hundreds)
Description