LEVIXO 40/60 24V RTS
7.2. List of settings (menus and sub-menus)
In the table, the value in bold type corresponds to the default value.
Menu
Sub-menu
Copyright
©
2017 SOMFY ACTIVITES SA. All rights reserved.
Val.
0 to 180 (10)
Automatic closing timeout
0 to 100 (40)
Calibrating the opening end limit (%)
0 to 100 (60)
Calibrating the closing end limit (%)
1 to 10 (3)
Acceleration at start of movement (%)
0 to 99 (70)
Deceleration distance (shi from operating speed to slowing speed) when opening and closing
expressed as a percentage of the total travel.
40 to 99 (75)
Force exerted by the barrier when opening (%)
40 to 99 (75)
Force exerted by the barrier when closing (%)
1 to 10 (2)
Braking during slowing phase (%)
15 to 99 (75)
Opening speed (%)
Setting of speed the barrier much reach when opening as a percentage of the maximum speed that
can be reached by the barrier.
15 to 99 (75)
Closing speed (%)
Setting of speed the barrier much reach when closing as a percentage of the maximum speed that
can be reached by the barrier.
0
Automatic closing not activated
1
Automatic closing activated
0
Quick closing not activated
1
Quick closing activated: closing 1s a er the cells are cleared without waiting for the end of the
automatic closing timeout configured
0
Operation 4 steps from the
radio-configured inputs
1
Operation 3 steps from
the radio-configured
inputs. A command sent
when closing reverses the
movement .
2
Operation 2 steps from the
radio-configured inputs. A
command sent when clos-
ing or opening reverses the
movement
0
Without notice before movement
1
With 3 s warning prior to movement
0
Pulse-controlled operation
1
"Dead man" operation
• Input 19 configured as OPEN UP
• Input 20 configured as CLOSED UP
Controlled by maintained action
Attention
Safety devices inactive
2
Emergency "dead man" operation is activated if the safety mechanism (photoelectric cells, etc.)
auto-tests fail 3 times in succession. Active 1 minute a er releasing the OPEN UP - CLOSE UP
buttons.
• Input 19 configured as OPEN UP
• Input 20 configured as CLOSED UP
Attention
Safety devices inactive
0
Pulse of radio-configured inputs takes effect during opening.
1
Pulse of radio-configured inputs does not take effect during opening.
0
Pulse of radio-configured inputs takes effect during TCA opening.
1
Pulse of radio-configured inputs does not take effect during TCA pause.
0
Pulse of radio-configured inputs takes effect during closing.
1
Pulse of radio-configured inputs does not take effect during closing.
0
Opening direction reversed in relation to standard operation (right-hand barrier)
1
Standard operation (le -hand barrier)
Description
2 STEPS
Closed
Open
When closing
opened
Close
Opening
A er STOP
Open
EN
3 STEPS
4 STEPS
Open
Open
Stop
Close
Close
Stop + closing
Stop + closing
timeout
timeout
Open
Open
7