Wiring Diagram - Shizuoka Seiki Co. VAL6 KBE1S Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

2
Remove the nozzle using the nozzle wrench
provided as standard parts.
Replace with a new nozzle.
Loosen
8
Specifications
Model Number
Type
Ignition System
Fuel
Fuel Consumption
Heat Output
Tank Capacity
Continuous Operating Time
Dimensions
Weight (Dry)
Power Supply

Wiring Diagram

PS
F
FG
Nozzle
VAL6KBE1S
Radiated direct fired
High intensity discharge
Kerosene or DIESEL
3.21 /h 2.67kg/h
28,000 kcal/h 32.5kW
35
10 hours
815(H) x 655(W) x 732(D) mm
Disk Diameter 562 mm
83.8 lbs, 38kgs.
AC230V (50Hz)
KAFM
HT
FM
PS
: Power Source
SW1 : Operation Switch
ALM : Short
TH
: Thermostat
FE
: Photo Cell
FG
: Flame Grand
HT
: Open
FM
: Fan Motor
3
Tighten the nozzle using the nozzle wrench
until the nozzle is fixed.
4
Put the burner assembly back with three nuts
removed.
Power Consumption
Electric Overload Fuse
Noise Level (in operation)
Safety System
Standard Parts
KASP
KAIG
CM
IG
SP
CM
: Open (Pre Heater)
IG
: Igniter
SP
: Solenoid Pump
RUN
: Running Lamp
MISFIRE : Misfire Lamp
KA*
: Control Relay
F
: Line Fuse
ES
: Earthquake Sensor (Short)
• When igniting: 85 W
• When burning: 60 W
• Optional : +50W for Preheater
1.6A
69dB (A)
• Flame Monitor (Flame Eye)
• Electric Overload System
• Fuse x 2
• Filter Element x 2
• Nozzle x 1
• Nozzle Wrench x 1
• Oil Seal x 2
SW1
TH
ALM
ES
FE
RUN
MISFIRE
13