Parker ServiceJunior SCJN Série Manuel D'utilisation page 79

Masquer les pouces Voir aussi pour ServiceJunior SCJN Série:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 129
SCJN-
Ambient condi-
tions
Data logger
(optional)
* Nominal pressure 630 bar, for pressure peaks up to 1000 bar
EMC Directive
Check of the test specimen for compliance with the EMC requirements
according to:
EN 61000-6-2:2005
EN 61000-6-3:2007 + A1:2011
V1.0/01/20
016
100
Ambient temperature: -10...+50 °C
(0...+50 °C for SCJN-xxx-x2)
Storage temperature: -20...+60 °C
Media temperature -20... + 80 °C
rel. humidity: < 85 %
Vibration: IEC 60068-2-6/10 ... 500 Hz, 5 g
Shock load: IEC 60068-2-29/25 g, 11 ms
Mini-USB connection with protective cap
Real time clock
Storage rate from 100 ms. Up to 18,000 read-
ings (automatic data compression)
Maximum measurement time: 24 hours
Number of measurements: 10
Storage format: CSV, Separator (dot or comma)
is adjustable
Technical data
400
600
1000
37

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Servicejunior scjr série

Table des Matières