Deviation for Germany:
When the range hood and appliances supplied with energy other than electricity are simulta-
neously in operation, the negative pressure in the room must not exceed 4 Pa (4x10 E-5 bar).
F
RECIRCULATING RANGE HOOD (with filter)
In this model, the area passes through the charcoal filters to be purified and is then recycled
into the kitchen environment. See sect. H for assembly.
G
OPERATION
1. ELECTRONIC CONTROL PANEL (PLANE NRS)
Light pushbutton
• ON: light on (the pushbutton is lit);
• OFF: light off;
Pushbutton -
Press to reduce motor speed
Speed 1, 2 and 3 are indicated by the number of LEDs that light up (excluding the light and
the timer LEDs).
Pushbutton +
Press to increase motor speed
Speed 1, 2 and 3 are indicated by the number of LEDs that light up (excluding the light and
the timer LEDs).
(In the 4-speed version the pushbutton + blinks. The fourth speed remains on for a set
duration of time. After 15 minutes the motor returns to the third speed).
Mode pushbutton
Function: it turns hood motor on and off.
The function "desired speed" enables to start the motor at the speed that was selected
before the hood was last turned off.
Optional: version with remote control (some versions only).
WARNING:
Install the hood away from sources of electromagnetic waves, as these could affect the
correct operation of the electronic system.
Maximum operating distance: 5 metres. The maximum operating distance could be less
than 5 metres in case of electromagnetic interference by other equipment.
Light pushbutton on remote control: light on/off.
– and + pushbutton: increase/decrease speed (to start the motor press either the + or the
– pushbutton).
Timer pushbutton: see instructions below.
Timer and 'filter clogged' alarm pushbutton
• This function allows the automatic turning off of the hood after running for 15 minutes at
the speed previously set (the pushbutton shows a flickering light).
• After about 30 hours of running the pushbutton indicates the need for washing the metal
filters (the pushbutton shows a solid red light). To disable the alarm press the pushbutton
for a few seconds until the red light turns off. Then turn the hood off and on again to check
that the alarm has disappeared.