Télécharger Imprimer la page

RIB AQM11 Instruction Pour Le Montage page 14

Coffret éléctronique pour le contrôle d'un moteur monophasé.

Publicité

Les langues disponibles

Les langues disponibles

pag. 14 di 24
C C O O N N T T R R O O L L U U N N I I T T C C O O N N F F I I G G U U R R A A T T I I O O N N
The control unit has two displays (FUNCtions and OPTions)
and 3 control buttons (ENTER for confirmation, ESC to exit
and TURN to display the various FUNCtions and
OPTions).
- To display the functions menu
press the ESC and TURN buttons simultaneously.
The following messages will
be displayed
PHASE SEQUENCE:
- Use the TURN button to select the required FUNCtion (FUNCtions F, 1, ..., 9,
A).
- Press the ENTER button to display the OPTions of the FUNCtions selected
(the decimal point of the FUNCtions display will disappear)
- Use the TURN button to memorise the displayed OPTion, the display will move
to the next OPTion.
- During this phase, pressing ENTER will activate or de-activate the OPTions.
- Press the ESC button to return to the FUNCtion selection (the decimal point of
the FUNCtion display will re-appear)
- To exit the programming, press the ESC button a second time.
EXPLANATORY DIAGRAM:
ENTER
ESC
ESC
ESC
TURN
The control unit is already configured for automatic operation of sliding
gate system with 1 single-phase motor, limit switch detectors, general and
pedestrian automatic closing.
FUNZ OPZ
ENTER
ESC TURN
OPTION SELECTION RANGE
ENTER
TURN
ENTER
SYSTEM CONFIGURATION PROGRAMMING
ESC to return to function menu
ENTER
1 motor
sliding (door)
w/out limit switch
-
-
-
-
without
electric lock
-
ENTER
Press the TURN
button to select a
period from 50ms to
maximum 850ms by
step 50ms
FUNCTION CHECK
Once all the connections have been made as shown in the diagram, it is good
practice to follow this procedure to prevent possible incorrect manoeuvring:
ENTER
- Place the automation system in stand-by (with ratio motor released and limit
switch detectors free).
- Keep the open button/selector (8-9) pressed and check that the motor opens
the gate (reverse wires V and W, leaving wire U unchanged).
- Keep the close button/selector pressed (8-11) and check that the leaf closes.
- Check the correct position of the limit switches.
- Fully close the gate and switch to time programming.
ESC
OPT 1 - OPERATING TIME ADJUSTMENT
Programming procedure:
ENTER
NOTE: The safety devices are also active during the time programming
procedure, therefore keep clear of the system. If the safety devices
intervene during manoeuvring while adjusting the times, the system will
stop. To return to the FUNCtion mode F, re-close the plant, return to FUNCtion
1 OPTion 1 and repeat the time programming procedure).
FUNCtion A
ENTER
2 motors
swing (door)
with limit switch
single-phase
three-phase
BT 12/24Vcc
double speed
with electric lock
Idro R. (add 7s
to closing time)
=0,05sec
Easier manual release
To make the manual release
easier, at the end of the closing
manouvre the
motor stops and
ENTER
starts the
opening
manouvre for
the period
=0,85sec
selected.
FUNCtion F
FUNCtion 1
TIME PROGRAMMING
ENTER

Publicité

loading