SYSTEM FOR AN OPEN TANK INSTALLATION
AN EXAMPLE OF A HYDRAULIC SYSTEM FOR A THERMO FIREPLACEITH HOT SANITARY WATER PRODUCTION AND A WALL MOUNTED BOILER
Electricity
RETE
ELETTRICA
Mains
VE
AF
V
S
TCN
ST
Ja
F
V
S
Kit N3 is designed to facilitate the work carried out by the installers. In fact, it consists of all the necessary components for the product to
be properly installed.
NB: insulating mats must be applied so that the components of the kit are well-protected from the heat radiation emitted by the
fireplace.
Components KIT N3
9
9
9
11
10
12
8
7
6
5
2
3
4
1
Electrical Connections
Sanitary-heating enabled setting
Enabled alarm
Electricity
Mains
T H E I N L E T A N D O U T L E T PI PE S M U ST B E C R O SS E D F O R T H I S TO F U N C TI O N PR O PE R LY
INT
KIT N3
CA
Circuito collegabile al
circuit connected to
termostato ambiente
the room thermostat
(a discrezione del cliente)
Sc
RE
(implemented by the
client)
P1
must be connected to the
Da collegare necessariamente
V
heating system circulator
al circolatore dell'impianto
Vs
di riscaldamento
PR
PR
VR
V
V
VR
VR
ACS
ACS
13
4
1
2
Passacavi
Cable duct
18
16 17
15
Primary circulator enabled setting
Primary circuit pump
Heating pump
TA
Water
AF
RETE
IDRICA
Mains
VR
V
VR
Collector
COLLETTORE
V
V
V
V
RI
MI
V
RA
V
7
6
14
5
3
Room thermostat
sensor
Flow sensor
USING
CA:
Wall Mounted Boiler
PR:
Pump (circulator)
P1:
Primary circuit pump
RE:
Electronic regulator
TA:
Room thermostat
VE:
Expansion Tank
Ja:
Air refief Valve
V:
Intercept valve
VR:
Retaining valve
ST:
Temperature Sensor
F:
Flow switch
Sc:
Heat plate exchanger
EV:
3-way solenoid valve
RI:
Heating system return
RA:
Radiators
MI:
Heating system flow
AF:
Cold water
ACS:
Hot sanitary water
S:
Drain
1
Heating system return G 3/4"
2
EDILKAMIN generator flow G 3/4"
3
EDILKAMIN generator return G 3/4"
4
Heating system flow G 3/4"
5
Cold sanitary water inlet G 1/2"
6
Hot water return to the sanitary system G 1/2"
7
Safety valve - temperature and pressure (90 °C - 3bar)
8
Flow Switch
9
Air relief valve G 3/8"
10
EDILKAMIN generator circuit circulator
11
3-way heat exchanger
12
Intercept valve G 1"
13
Electronic regulator with wiring
14
Appropriate aperture for the cable duct to pass through
15
Power cable
16
Cables for the heating system circulator
17
Temperature sensor
18
Room thermostat circuit
KIT N3
KIT N3
(
phase, neutral, earth)
code 627690
27