[BAT. TEMP TOO LOW
]
Batt. temperature is too
low to be operated.
[BAT. TEMP TOO HIGH ]
Battery temperature too high (this message only appears if the temperature sensor is connected and attached to the
Batt. temperature is too
battery). WARNING: if you ignore the warning and charge the battery, it may be damaged! Fire hazard!
high to be operated.
The charger has overheated. Allow it cool down, then try again.
[
INTERNAL TEMP
]
Internal temperature is too
hot.
Communication error. Send the charger to a Graupner service point.
[DATA COMMUNICATION ]
Contact Service.
This warning appears if a LiXX battery is connected to the balancer output, and the charger detects too high a cell voltage
[BALANCER VOLT. HIGH]
for the selected battery type. Check the battery type setting and correct if necessary.
Balancer Voltage is too
high.
This warning is generated if a LiXX battery is connected to the balancer output, and the charger detects too low a cell
[BALANCER VOLT. LOW ]
voltage for the selected battery type. Check the battery type setting and correct if necessary.
Balancer Voltage is too
low.
You will see this warning if a LiXX battery is connected to the balancer output, and the charger detects a cell count which
[BALANCER CONNECTOR ]
does not match the set cell count. Check the cell count setting and correct if necessary.
Selected cells and battery
cells different.
You will see this warning if a LiXX battery will not be charged in the LiXX mode. Select the right charging mode.
[ NO BALANCER MODE
]
Do not charge LiXX with
this mode.
<NOTICE!!>
Note: balancer lead connected to charger.
B a l a n c e r c o n n e c t o r
c o n n e c t e d .
<NOTICE!!>
Note: balancer lead not connected to charger; connect lead.
B a l a n c e r c o n n e c t o r
n o t c o n n e c t e d .