NV300 Handbook
† Table1: Output Voltage Cross Reference
Designation
0
A
1
B
2
3
5
7
T
F
G
All channels are adjustable except for Channel 4 and Global Options in accordance with the following table:
Voltage
Output Channel
designation
CH1
CH2 (CH1 5V)
CH2 (CH1 12V)
CH2 (CH1 24V)
CH3
CH4
CH4 (fan output)
Global Option
Variations and limitations of use:
1.
Maximum 300W power output. With 180Vac and greater input voltage, output power 300W plus global option
(max 313.5W)
2.
Channels 1 and 2 combined output currents must not exceed 40A.
3.
Channel 1 with G output, 25V max with any channel 2 fitted.
Additional variations and limitations of use for fan version with 5V channel 1:
1.
Output power de-rated 3W per volt from 100Vac to 90Vac (at 90Vac input, 270W output)
2.
Unit with global option, high current channel 2 de-rated to 21A
Output Voltage
Omit output
1.5
1.8
2
2.7
3.3
5
7
12
15
24
Vout (V)
5
5
T
12
G
24
1
1.8
2
2.7
3
3.3
3H
3.3
5
5
5H
5
5
5
5H
5
T
12
F
15
T
12
F
15
TH
12
FH
15
G
24
3H
+/-3.3
5H
+/-5
T
+/-12
F
+/-15
TH
+/-12
FH
+/-15
OH
-
N3
5 (ATX version)
N4
12 (ATX version)
N5
13.5 (ATX version)
Adjustment
Output
Range (V)
Current (A)
5 - 5.5
40A
12 – 13.2
25A
24 - 28.5
12.5A
0.9 – 2.5
15A
2.5 - 3.8
15A
2.5 - 3.8
15A
2.5 – 3.8
24A
3.3 - 5.5
10A
3.3 - 5.5
16A
5 - 5.5
5 - 5.5
12.5A
12 - 15.5
10A
12 - 15.5
10A
12 - 15
12 - 15
12 - 15
12 - 15
18 - 24.5
2.5A
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
-
Fixed
Fixed
Fixed
Page 15 of 25
Max Power
(W)
200
300
300
37.5
50
50
80
50
80
8A
40
62.5
150
150
5A
60
5A
60
8A
96
8A
96
60
2A
6.6
2A
10
1A
12
1A
15
2A
24
2A
30
-
-
2A
10
1A
12
1A
13.5
17173 issue 14, October 2018