Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 18
INSTRUCTIONS FOR USE
4. When the engine is started, one of the three results will be shown together with the reading of the measured voltage.
Result: OK
The system shows normal starting voltage. Press "EXIT" and "Alternator Test" to test the
charging system.
Result: Abrupt Voltage Drop
The starting voltage is below normal limits; find the starter motor fault following the manufac-
turer's recommended instructions.
Result: Not Detected
The starting voltage was not detected.
RECHARGE SYSTEM VOLTAGE TEST, "ALTERNATOR TEST", WITH ELECTRIC LOADS OFF
1. If the starting voltage is normal, press "EXIT" and "Alternator Test" to perform the
charge system test. Switch off all the accessories of the vehicle being tested, inclu
ding lights, air conditioner, radio etc. before starting the engine.
2. Press "Enter" to view the following screen:
Start the engine and keep it running. Press "Enter" to continue.
3. The following screen will appear:
Press "Enter" to continue. Rev the engine to 3,000 rpm for 10 seconds; then press
"Enter" again to view the results.
4. The following screen will appear:
5. Press "Enter" again; one of the three results will be displayed along with the current measured reading.
14
EN
Result: OK
Min. Volts: xx.xxV
Volt Drop: Normal
Result: High Voltage Drop
Min. Volts: xx.xxV
Volt Drop: High
Check starter relay,
battery terminals or
battery age.
Result: Not detected
No change in volt drop.
Check clamping at battery
side and test again.
Select Test ▲▼
Battery Test
Grounding Test
Starter Test
Alternator Test
Start engine
and keep it running.
[Enter] to proceed
Make sure all electrical
loads are turned off.
Rev engine to 3,000 rpm
Press [Enter].
Hold on to this 3,000 rpm
for 10 seconds, then release
pedal
A 3.000 rpm:
Av.Volts:
xx,xV
Max. xx,xV <xx,xV
Min. xx,xV >xx,xV

Publicité

Table des Matières
loading

Table des Matières