Publicité

Liens rapides

INSTALLATION
MANUAL
R410A SPLIT SERIES
MODELS
FTXN25LV1B
FTXN35LV1B
FTXN50LV1B
FTXN60LV1B
Серия R410A с раздельной установкой
RXN25LV1B
RXN35LV1B
RXN50LV1B
RXN60LV1B
Installation Manual
R410A Split Series
Manuale d'installazione
Serie Multiambienti R410A
Installationsanleitung
Split-Baureihe R410A
Manual de instalación
Serie Split R410A
Manuel d'installation
Série split R410A
Montaj kýlavuzlarý
R410A Split serisi
Руководство по монтажу
IM-5WMYJ-0811(4)-DAIKIN
Part Number: R08019036974D
E ngl is h
I taliano
Deutsch
E spa ñol
Fr ançais
Tür kçe
Р усский

Publicité

Table des Matières
loading

Sommaire des Matières pour Daikin FTXN25LV1B

  • Page 1 Serie Split R410A Manuel d’installation Fr ançais Série split R410A Montaj kýlavuzlarý Tür kçe R410A Split serisi Руководство по монтажу Р усский Серия R410A с раздельной установкой MODELS FTXN25LV1B RXN25LV1B FTXN35LV1B RXN35LV1B FTXN50LV1B RXN50LV1B FTXN60LV1B RXN60LV1B IM-5WMYJ-0811(4)-DAIKIN Part Number: R08019036974D...
  • Page 3: Outline And Dimensions

    OUTLINE AND DIMENSIONS Indoor Unit THE MARK SHOWS PIPING DIRECTION REAR REAR LEFT RIGHT TOP VIEW NAME PLATE SIGNAL RECEIVER TERMINAL BLOCK WITH EARTH INDOOR UNIT TERMINAL BOTTOM BOTTOM ON/OFF SWITCH SIDE VIEW ROOM TEMPERATURE THERMISTOR (INSIDE) LOUVER FRONT GRILLE FIXED SCREWS (INSIDE) FRONT VIEW Use tape measure...
  • Page 4 Recommended mounting plate retention spots (7 spots in all) Through the wall hole Ø 65mm Drain hose Liquid pipe end Gas pipe end position INSTALLATION PLATE FTXN50/60LV1B All dimensions are in mm Dimension Model FTXN25/35LV1B FTXN50/60LV1B 1065 Outdoor Unit [RXN25/35LV1B] All dimensions are in mm Dimension Model...
  • Page 5 Outdoor Unit [RXN50/60LV1B] All dimensions are in mm Dimension Model RXN50/60LV1B Dimension Model RXN50/60LV1B...
  • Page 6: Safety Precautions

    INSTALLATION MANUAL This manual provides the procedures of installation to ensure a safe and good standard of operation for the air conditioner unit. Special adjustment may be necessary to suit local requirements. Before using your air conditioner, please read this instruction manual carefully and keep it for future reference. This appliance is intended to be used by expert or trained users in shops, in light industry and on farms, or for commercial use by lay persons.
  • Page 7: Important

    IMPORTANT Important information regarding the refrigerant used This product contains fl uorinated greenhouse gases covered by the Kyoto Protocol. Do not vent gases into the atmosphere. Refrigerant type: R410A value: 1975 GWP = global warming potential Please fi ll in with indelible ink, A the factory refrigerant charge of the product, B the additional refrigerant amount charged in the fi...
  • Page 8: Installation Diagram

    INSTALLATION DIAGRAM Indoor Unit Cut thermal insulation pipe to an appropriate length and wrap 30mm or more from ceiling Caulk pipe it with tape, making sure that no hole gap gap is left in the insulation pipe’s with putty. cut line. Front Panel Wrap the insulation pipe with the 50mm or more from walls...
  • Page 9 Drain work. (Heat Pump Unit Only) 1) Use drain plug for drainage. 2) If the drain port is covered by a mounting base or fl oor surface, place additional foot bases of at least 30mm in height under the outdoor unit’s Drain water hole feet.
  • Page 10: Installation Of The Indoor Unit

    INSTALLATION OF THE INDOOR UNIT The indoor unit must be installed in such a way so as to The refrigerant piping can be routed to the unit in a prevent short circuit of the cool discharged air with the hot number of ways (left or right from the back of the unit), by return air.
  • Page 11: Water Drainage

    Mounting Installation Plate Hole with cone drill Ensure that the wall is strong enough to withstand the Inside Outside Wall embedded pipe weight of the unit. Otherwise, it is necessary to reinforce (Field supply) Caulking the wall with plates, beams or pillars. Use the level gauge for horizontal mounting, and fi...
  • Page 12 Additional refrigerant charge [g] per additional 1m length as tabulated Indoor FTXN25LV1B FTXN35LV1B FTXN50LV1B FTXN60LV1B Outdoor RXN25LV1B RXN35LV1B RXN50LV1B RXN60LV1B Additional charge [g/m] Example: FTXN25LV1B & RXN25LV1B with 12m piping length, additional piping length is 4.5m. Thus, Additional charge = 4.5[m] x 20[g/m] = 90.0[g] 1-10...
  • Page 13: Refrigerant Piping

    REFRIGERANT PIPING • When tightening the fl are nut with the torque wrench, Piping Works and Flaring technique ensure that the tightening direction follows the arrow • Do not use contaminated or damaged copper tubing. If indicated on the wrench. any piping, evaporator or condenser had been exposed •...
  • Page 14: Electrical Wiring Connection

    ELECTRICAL WIRING CONNECTION IMPORTANT :* The fi gures shown in the table are for information purpose only. They should be checked and selected to comply with the local/national codes of regulations. This is also subject to the type of installation and conductors used. The appropriate voltage range should be checked with label data on the unit.
  • Page 15 SPECIAL PRECAUTIONS WHEN DEALING WITH R410A UNIT R410A is a new HFC refrigerant which does not damage • Use tools and materials exclusively for refrigerant the ozone layer. The working pressure of this new R410A. Tools exclusively for R410A are manifold valve, refrigerant is 1.6 times higher than conventional refriger- charging hose, pressure gauge, gas leak detector, flare tools, torque wrench, vacuum pump and refrigerant...
  • Page 16: Indicator Lights

    INDICATOR LIGHTS IR Signal Receiver When an infrared remote control operating signal has been transmitted, the signal receiver on the indoor unit will respond as below to confi rm acceptance of the signal transmission. ON to OFF 1 Long Beep OFF to ON 2 Short Beep Pump down / Cool force on...
  • Page 17: Operating Range

    OPERATING RANGE Model: FTXN25/35LV1B RXN25/35LV1B COOLING HEATING 14 15 19 20 INDOOR TEMP. (°CWB) INDOOR TEMP. (°CDB) DB: Dry bulb WB: Wet bulb Model: FTXN50/60LV1B RXN50/60LV1B COOLING HEATING 14 15 19 20 INDOOR TEMP. (°CWB) INDOOR TEMP. (°CDB) DB: Dry bulb WB: Wet bulb 1-15...
  • Page 18: Air Filter

    AIR FILTER 1. Open the front panel. 3. Clean or replace each fi lter. • Hold the panel at the recesses on the main unit (2 • When shaking off remaining water, do not wring the recesses on right and left sides) and lift it until it fi...
  • Page 19 CAUTION • Avoid direct contact of any oil treatment cleaners on plastic part. This may cause plastic part to deform as a result of chemical reaction. 1. Open the front panel. • Hold the panel at the recesses on the main unit (2 Recess on main unit recesses on right and left sides) and lift it until it...
  • Page 20 MEMO...
  • Page 21 08 S declara sob sua exclusiva responsabilidade que os modelos de ar condicionado a que esta declaração se refere: 25 Z tamamen kendi sorumluluğunda olmak üzere bu bildirinin ilgili olduğu klima modellerinin aşağıdaki gibi olduğunu beyan eder: FTXN25LV1B, FTXN35LV1B, FTXN50LV1B, FTXN60LV1B, ATXN25LV1B, ATXN35LV1B, ATXN50LV1B, ATXN60LV1B, 01 are in conformity with the following standard(s) or other normative document(s), provided that these are used in accordance with our 08 estão em conformidade com a(s) seguinte(s) norma(s) ou outro(s) documento(s) normativo(s), desde que estes sejam utilizados de...
  • Page 22 02 ** Daikin Europe N.V. hat die Berechtigung die Technische Konstruktionsakte zusammenzustellen. 08 ** A Daikin Europe N.V. está autorizada a compilar a documentação técnica de fabrico. 14 ** Společnost Daikin Europe N.V. má oprávnění ke kompilaci souboru technické konstrukce.
  • Page 23 02 ** Daikin Europe N.V. hat die Berechtigung die Technische Konstruktionsakte zusammenzustellen. 08 ** A Daikin Europe N.V. está autorizada a compilar a documentação técnica de fabrico. 14 ** Společnost Daikin Europe N.V. má oprávnění ke kompilaci souboru technické konstrukce.
  • Page 24 DAIKIN EUROPE N.V. Importer for Turkey: Zandvoordestraat 300, B-8400 Oostende, Belgium. AIRFEL ISITMA VE SOGUTMA SISTEMLERI SANAYI Zandvoordestraat 300, B-8400 Oostende, Belgium DAIKIN ISITMA VE SOGUTMA SISTEMLERI TICARET A.S. SANAYI TICARET A.S. Hurriyet Mah.E5 Yanyol, Uzeri No.57, Hurriyet Mah.E5 Yanyol, Uzeri No.57, 34876, Kartal Istanbul.

Table des Matières