When installing the ducted version, connect the hood to the
chimney using either a flexible or rigid pipe ø 150 or 120 mm,
the choice of which is left to the installer.
• To install a ø 120 mm air exhaust connection, insert the re-
ducer flange 9 on the hood body outlet.
• Fix the pipe using the pipe clamps 25 provided.
• Remove any activated charcoal filters.
RECIRCULATION VERSION AIR OUTLET
• Insert the reducer flange 9 on the air outlet of the extractor.
• Attach the adhesive Novastik gasket 13 to the air outlet con-
nection 15 and fix this to the upper frame using the 2 knobs 24.
• Fix the air outlet connection extension piece 14 to the air outlet
connection 15.
• Connect the hood air outlet to the flange in the lower part of
the junction using a rigid or flexible ø 120 tube (by installer's
choice).
EN
ø 150
ø 120
25
24
15
14
14
9
25
9
15
15
9 9