Specifications
1-1 General Specifications
LCD display digits :
3 3/4 digit large scale LCD readout.
Display count : 4000 counts.
Measuring rate : 1.5 times / sec.
Overrange display :
"OL" is displayed for "Ω" functions,
shows the real value for "A" and "V" and "
°C/°F "function.
Automatic power off time :
Approximately 10 minutes after power on.
Low battery indicator : is displayed.
Power requirement : 9V battery
Battery life : ALKALINE 9V 200 hours
1-2 Environmental Conditions
Indoor Use.
Calibration : One year calibration cycle.
Operating temperature :
0°C ~ 30°C (≦80% RH)
30°C ~ 40°C (≦75% RH)
40°C ~ 50°C (≦45%RH)
Storage temperature :
-20 to +60°C, 0 to 80% RH (batteries not
fitted).
Overvoltage category :
IEC 61010-1 600V CAT.Ⅲ.
CAT
Application field
Ⅰ
The circuits not connected to Mains.
The circuits directly connected to
Ⅱ
Low-voltage installation.
Ⅲ
The building installation.
The source of the Low-voltage
Ⅳ
installation.
Operating altitude : 2000m (6562 ft)
Conductor Size : 32mm diameter.
Pollution degree : 2
EMC : EN 61326-1
Shock vibration :
Sinusoidal vibration per MIL-T-28800E (5
~ 55 Hz, 3g maximum).
20