WARNING To ensure an appropriate level of electrical safety always keep the 230V cables (power
supply) apart from low voltage cables (motors power supply, controls, aerial and auxiliary circuits power
supply), and fasten the latter with appropriate clamps near the terminal boards.
WARNING Any installation, maintenance or repair operation on the whole system must be carried
out exclusively by qualified personnel. All these operations must be performed only after disconnecting
the power supply, and operating in strict compliance with the electrical standards and regulations in
force in the nation of installation.
WARNING Install and wire the control board according to the instructions given in the instruction
booklet of each gate operator DEA System (such as hole drilling to allow for wires passage, use of wire
clamps, etc.)
Failure to comply with these instructions may jeopardize the level of electrical safety.
WARNING During motor stroke memorization, the control board detects automatically the presence
and type of photocells, safety devices and limit switches which are installed. It is therefore essential that
during this phase the latter be properly connected and working.
WARNING Wrong assessment of impact forces may cause serious damage to people, animal and
things. DEA System reminds all personnel that the installer must ascertain that these impact forces,
measured according to EN 12445 prescriptions, are actually below the limits indicated by EN12453
regulation.
WARNING Any external safety device installed in order to conform to the limits set for impact forces
must comply with EN12978.
WARNING Using spare parts not indicated by DEA System and/or incorrect re-assembly may en-
danger people, animals and property, and may also cause malfunctioning of the product: always use
parts provided by DEA System and follow assembly instructions.
WARNING Disposal of packaging materials (such as plastic, card board, etc.) must be done ac-
cording to regulations in force locally. Do not leave plastic bags and polystyrene within the reach of
children
3 MODELS AND CONTENTS OF THE PACKAGE
124RR control boards may be supplied separately for external installation
•124RRC inside an IP55 rated box (with 150 V A transformer)
•124RRCB either inside an IP55 rated box (with 150 V A transformer and 2 batteries 12V - 1.2 Ah)
or incorporated within the DEA System automation:
•124RR -for 3/24RR, 6/24RR, PASS/24 (with 80 V A transformer) automation
-for 905/24RR, 1000/24, 1001/24 (with 150 V A transformer) automation
•124RRS for 10/24RRS automation (with heat dissipater and 250 V A transformer)
4 PRODUCT DESCRIPTION
124RR control board is designed for the automation of DEA System gates operators in 24 V
therefore it is fit for overhead doors, sliding gates and barriers. It is extremely versatile, easy to install and
fully complies with European regulations concerning electromagnetic compatibility and electric safety
Main features of the product:
1. setting all parameters by 3 keys and a 4-digit display;
2. possibility of fine tuning of motor speed both during its complete stroke and during the last phase of it
(slow-down). It keeps motor torque even at very low speed;
3. possibility to set at will the slow-down duration;
4. Internal anti-crash safety device whose sensitivity can be adjusted (according to a 70-level scale) sepa-
rately in both operating directions;
5. inputs to connect both normal and powered external safety devices (mechanical ribs or photocell bar-
riers), with the possibility to run a self-test before each operation. Controlled photocells;
6. built-in 433,92MHz radio receiver for both HCS and HT12E coding offering the possibility to search
and delete each transmitter separately
Operating instructions and warnings
A4
A5
A 6
A7
A8
A9
A10
A11
, and
15
1 2 4 R R