DSC IT-100 Instructions D'installation page 2

Publicité

Table 1: Recommended baud rate settings per cable length:
Baud Rate
Cable Length *
9600
19200
38400
57600
115200
* Cable capacitance 50pF/ft
Table 2: Status Reporting via LED
LED
Status
Off
Module is not powered
Solid
Module is powered but communication
with panel is not initiated from start up
Flashing every ½
Module is powered and is receiving/sending
second
data with panel
Flashes 2 seconds off and
Module is powered but there is a Trouble
½ second on
with the Keybus connection
LED
RED
BLK
YEL GRN
To Panel
V ers le Tableau
Al Panel
2 9 0 0 7 3 0 2 R0 0 2
©2006 Digital Security Controls Toronto, Canada • www.dsc.com
Tech. Support/Centre d'aide technique/Líneas Tech:1-800-387-3630 (Canada & U.S.), 905-760-3036
Tableau 1: Ajustements recommandés du taux de bauds par
longueur de câble :
Taux de Bauds
98' (30m)
50' (15.2m)
25' (7.6m)
20' (6m)
8' (2.4m)
* Capacité du câble 50pF/m
Tableau 2: Rapports de status par LED
LED
Débranché
Solide
Clignotant à chaque ½
seconde
Il clignote avec la
fréquence de 2 secondes
éteint et ½ seconde allumé
RS-232
To Application
Vers l'Application
a aplicación
Install the ferrite inside the control panel as close to the IT-100 as allowable.
Installez la ferrite à l'intérieur du panneau de contrôle aussi près que permis du IT-100.
Instale la ferrita dentro del panel de control lo más cerca posible del IT-100.
Figure A
Longueur du câble *
9600
30 m (98')
19200
15 m (50')
38400
7,5 m (25')
57600
6 m (20')
115200
2,4 m (8')
Status
Le module n'est pas alimenté
Le module est alimenté mais la
communication avec le tableau n'est pas
initialisée depuis l'initialisation.
Le module est alimenté et reçoit/transmet
des données avec le tableau
Le module est alimenté mais il y a un
Problème avec le raccord Keybus
Keybus Connection
Connexion de keybus
Conexión del keybus
Keybus Wires (loop 2 times)
Fils de keybus (boucle 2 fois)
Alambres del keybus (lazo 2 veces)
Panel
IT-100
Panneau
Ferrite
(DSC PN 10000054)
Tabla 1: Ajustes recomendados de la tasa de baudios por largo
de cable:
Tasa de Baudios
9600
19200
38400
57600
115200
* Capacidad del cable 50pF/m
Tabla 2: Informes del Status a través del LED
LED
Apagado
Sólido
Intermitente a cada ½
segundo
Se pone intermitente con la
frecuencia de 2 segundos
apagado y ½ segundo
encendido
FCC COMPLIANCE STATEMENT
CAUTION: Changes or modifications not expressly approved by Digital Security Con-
trols could void your authority to use this equipment.
This equipment generates and uses radio frequency energy and if not installed and
used properly, in strict accordance with the manufacturer's instructions, may cause
interference to radio and television reception. It has been type tested and found to
comply with the limits for Class B device in accordance with the specifications in
Subpart "B" of Part 15 of FCC Rules, which are designed to provide reasonable pro-
tection against such interference in any residential installation. However, there is no
guarantee that interference will not occur in a particular installation. If this equip-
ment does cause interference to television or radio reception, which can be deter-
mined by turning the equipment off and on, the user is encouraged to try to correct
the interference by one or more of the following measures:
- Re-orient the receiving antenna
- Relocate the alarm control with respect to the receiver
- Move the alarm control away from the receiver
- Connect the alarm control into a different outlet so that alarm control and receiver
are on different circuits.
If necessary, the user should consult the dealer or an experienced radio/television
Figure B
technician for additional suggestions. The user may find the following booklet pre-
pared by the FCC useful: "How to Identify and Resolve Radio/Television Interfer-
ence Problems". This booklet is available from the U.S. Government Printing
Office, Washington D.C. 20402, Stock # 004-000-00345-4.
IC STATEMENT
This Class B digital apparatus meets all requirements of the ICES-003.
Cet appareil numérique de la classe B respecte toutes les exigences du ICES-003.
Printed in Canada / Imprimé au Canada / Impreso en Canadá
Largo del Cable *
30 m (98')
15 m (50')
7,5 m (25')
6 m (20')
2,4 m (8')
Status
El módulo no está alimentado
El módulo está siendo alimentado, pero la
comunicación con el panel no es iniciada
desde la iniciación
El módulo está siendo alimentado y está
recibiendo / transmitiendo datos con el
panel
El módulo está siendo alimentado, pero
hay un Problema con la conexión Keybus

Publicité

loading